Functional Scope Of Engine, PSM, Function - GF54.21-D-3007TSC
Model 907
with code ED5 (Parameterisable special module)
Power take-off
Engine functions
The parameterizable special module (PSM) control unit enables functions in the engine control unit to be influenced.
The parameterizable power take-off function module is implemented, which guarantees correct operation of the engine control unit.
Power take-off function
The power take-off function on vehicles with power take-off is used to control activation of the power take-off.
To prevent damage to the transmission, various conditions can be queried.
Power take-off
Power take-off function
The power take-off (PTO) module enables a device driven by the engine to be connected or disconnected from the main transmission as and when required. The PSM control unit controls the solenoid valve here for the power take-off, which triggers the hydraulic activation of the power take-off.
In the power take-off, the following input conditions can be influenced for internal function enabling:
- Parameterization of internal inputs via menu item "Special functions → Power take-off, input":
- Requirements for enabling power take-off: Transmission in neutral position
- Requirements for enabling power take-off: Freely parameterizable CAN signal
- Parameterization of power take-off (PTO) module via menu item "Special functions → Power take-off, properties":
- Function "Power take-off"
- Requirement for enabling of power take-off: Parking brake
- Requirement for enabling of power take-off: Engine at idle
- Requirement for enabling of power take-off: Clutch
If all set conditions are met, the "Request for power take-off over an input function" input or the "Request for a power take-off over the body manufacturer CAN function" input of the "power take-off" module, the power take-off solenoid valve can be activated.
The menu item "Special functions Power take-off, input" can be used to parameterize the internal inputs for the power take-off (PTO) module.
Request for function "Power take-off" via an input
Request for activation of power take-off. Activation of the power take-off takes place when all of the set conditions are fulfilled.
If the parameter "Activation of power take-off despite unfulfilled switch-on conditions" is set to "YES" in the power take-off (PTO) module, the user can override an unfulfilled condition by pressing the push button switch several times.
In this case, a fault entry (B) is made. If the user presses the pushbutton only once, the power take-off is not activated and only an event entry (B182D9A) is made. The fault freeze frame data of the event (B182D9A) indicates which requirements were not fulfilled at the time of the request. The information as to which switch-on requirement was overruled by the user can be found in the actual values.
Parameterization possibilities:
- Any signal: Any signal can be used here.
- Continuous low (signal ID 0x1000): Function deactivated
Request for "Power take-off" function over body manufacturer CAN
Request over body manufacturer CAN for activation of power take-off.
Setting of the fault code (B182D9A). The fault freeze frame data of the event (B182D9A) indicates which requirements were not fulfilled at the time of the request. The information can be found in the actual values.
Parameterization possibilities:
- Any signal from body manufacturer CAN: Any signal from the body manufacturer CAN can be used here.
- Continuous low (signal ID 0x1000): Function deactivated
Requirement for enabling power take-off: Transmission in neutral position, with transmission 722.9
The availability of the signal depends on the vehicle equipment.
Activation input (bit signal) as condition for power take-off.
Parameterization possibilities:
- Selector lever in position "N" (signal ID 0x1521): Querying of selector lever neutral position for activation of power take-off.
- Query DEACTIVATED (signal ID 0x30BE): Querying of this condition deactivated
Requirement for enabling power take-off: Freely parameterizable CAN signal
Activation input as condition for power take-off.
The procedure is as follows:
- Signal = Any signal
- Type of signal = Bit or other signal
- Type of evaluation:
- With bit signal = Signal inverted or non-inverted
- For other signals = Signal is above or below threshold value.
Parameterization possibilities:
- Any signal: Any signal can be used here.
- Query DEACTIVATED (signal ID 0x30BE): Deactivated
Further parameters for freely parameterizable CAN signal "Power take-off"
These must be parameterized in the module:
- Threshold (value range = 0 to 65 535)
- Threshold evaluation, selection = Value must be higher or lower than threshold.
- Invert (only with bit signals), selection = "Yes" or "No"
Feedback from power take-off
Input to which the power take-off feedback is connected.
Parameterization possibilities:
- Any discrete input: Any input can be used here.
- Continuous low (signal ID 0x1000): Function deactivated
If you wish to evaluate feedback through the PSM control unit, you have to set the parameter "Power take-off feedback to be evaluated" to "YES" in the power take-off (PTO) module.
The module can be parameterized via the menu item "Special functions → Engine start and engine stop, properties".
Function "Power take-off"
The "Power take-off" module can be activated and deactivated with this parameter.
Requirement for enabling of power take-off: Parking brake
This parameter can be used to activate or deactivate the "Parking brake OPERATED" requirement.
Requirement for enabling of power take-off: Engine at idle
This parameter can be used to activate or deactivate the "Engine in idle" requirement.
Requirement for enabling of power take-off: Clutch
The availability of the signal "Clutch pedal FULLY DEPRESSED" depends on the vehicle equipment.
This query cannot be deactivated, as otherwise the power take-off may be damaged. You can only choose between "Clutch pedal DEPRESSED" and "Clutch pedal FULLY DEPRESSED".
The switch "Clutch pedal FULLY DEPRESSED" is installed on vehicles with at least one of the following:
- With code B25 (Electric parking brake)
- With code E07 (Hill-Start Assist)
- With code GE9 (6-speed manual transmission)
- With CODE MJ8 (ECO start/stop function)
- With code M53 (Constant RPM control)
- With CODE MS1 (CRUISE CONTROL)
- With code MT4 (Variable electronic RPM governor)
- With code MW1 (Engine run-on control)
Limitation of type-tested maximum speed over "Power take-off" function
When the power take-off is switched on, the design-dependent maximum speed of the vehicle can be limited here. Speeds of 1 km/h to 255 km/h can be parameterized.
Activation of power take-off despite unfulfilled switch-on conditions
If this option is set, an unfulfilled condition for the power take-off can be overridden by resetting or setting the power take-off request. The fault freeze frame data of the event (B182D9A) indicates which requirements were not fulfilled at the time of the request. The information can be found in the actual values. If this option is not set, the power take-off solenoid valve can only be actuated once all conditions are fulfilled and the power take-off request can then be subsequently set.
Speed limit for deactivation of power take-off
The current vehicle speed is compared with the parameter "Vehicle speed limit for power take-off shutoff" and the result of this comparison is used as the input signal for deactivation of the power take-off.
If the parameter "Vehicle speed limit for deactivation of power take-off" is set to 255, checking of the vehicle speed is deactivated in the power take-off (PTO) function module.
Limitation of maximum engine speed via "Power take-off" function
This RPM limitation is issued if the power take-off is active.
For technical reasons, the parameter can only be adjusted in a range of 1200 to 2500 RPM.
Clutch waiting time
The clutch status must be "Clutch depressed or fully depressed" for a period of 5 s in order for this condition to be regarded as fulfilled in the solenoid valve actuation (MVA) module.
For technical reasons, this parameter is permanently stored in the PSM control unit. No settings can be made here.
Signals from "Power take-off" function hat are stored in the signal pool
Request for working speed control (module "Power take-off")
This bit signal is used as a request signal for working speed control. It is set in the power take-off (PTO) module.
This signal is set when the inputs of the power take-off (PTO) module are valid and one of the power take-off requests (input, body manufacturer CAN) is active.
Actuate solenoid valve for power take-off (module "Power take-off")
This bit signal is used as the request signal for actuation of the power take-off solenoid valve. It is set in the power take-off (PTO) module.
This signal is set when the inputs of the power take-off (PTO) module are valid and one of the power take-off requests (input, body manufacturer CAN) is active.
If you want to implement actuation of the power take-off through the PSM control unit, you must set the "Actuation of solenoid valve through PSM control unit" parameter to "YES" in the module and send the signal 0x1241 (Power take-off engaged) to one of the discrete outputs of the PSM control unit.
Solenoid valve actuation module (MVA)
Power take-off (PTO) module
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |