Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System, Equipment & Instructions - Description & Operation, Location, Gen Info & Basic Knowledge >> Basic Knowledge >> Combustion Engine Signal List, PSM Function - GF54.21-D-3046TSA

Combustion Engine Signal List, PSM Function - GF54.21-D-3046TSA

Model 907 

with code ED5 (Parameterisable special module) 

COMBUSTION ENGINE

Signal name Signal ID Description Signal type Default value
MSTOP_engine_stop 0x1441 Engine stop signal Bit 0
MSTART_engine_start 0x1442 Engine start signal Bit 0
PTO_ADR_request 0x1443 Power take-off module request for working speed control. Bit 0
PTO_indicator lamp_disk 0x1444 Actuates the power take-off indicator lamp. Bit 0
PTO Valve actuation 0x1445 Request to solenoid valve control. Bit 0
MVS_PTO_engaged 0x1446 This signal is set when the solenoid valve of the power take-off is actuated and the feedback from the power take-off is also active. Bit 0
MVS_valve_actuation 0x1447 Actuates the solenoid valve for the power take-off. Bit 0
FDZB_enable 0x1448 Enable signal for the fixed speed specification and rpm limitation modules. Bit 0
ADR_Enable 0x1449 Enable signal for the working speed control (ADR) modules. Bit 0
DZA_target_engine_speed 0x730B Speed specification value of speed modification module, is sent over the interior CAN. Normalization: 1 bit = 1 rpm. Data word (Word) 65 535
DZA_switch_actuation 0x144A Is set as soon as a switch for changing speed has been pressed. Bit 0
DZB_Akt_MaxSpeed 0x830B Current maximum rpm limitation. Normalization: 1 bit = 1 rpm. Data word (Word) 65 535
DZB_Current_MinSpeed 0x930B Current minimum rpm limitation. Normalization: 1 bit = 1 rpm. Data word (Word) 0
DZB_Akt_MaxSpeed 0x30BA Current maximum speed. Normalization: 1 bit = 1 km/h. Data word (Word) 65 535
DZB_Akt_MaxTorque 0x30BB Current maximum torque. Data word (Word) 65 535
FDZ_rpm_output 0x30BC Output of fixed speed specification module. Normalization: 1 bit = 1 rpm. Data word (Word) 65 535
HFG_rpm_specification 0x30BD Output of hand-throttle actuator module. Normalization: 1 bit = 1 rpm. Data word (Word) 65 535
PUR_ramp_mode 0x144B If set, the speed modification module generates a speed ramp. Bit 0
ADR_accelerator_pedal_lock 0x144C If set, the accelerator pedal lock is active on the interior CAN. Bit 0
VBEG_speed_limit 0x20ED Speed limit. Byte 0xff
VBEG_speed_limit_active 0x144D Speed limit is active. Bit 0
ADR_input_inactive 0x30BE Supplies an inactive signal for use with the function inputs of the engine functions. Data word (Word) 0xFFFF