LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> Electrical System, Equipment & Instructions - Removal & Installation (5 Of 8)) >> Removal & Installation >> Code Signal Acquisition And Actuation Module (Code: Vs3WABLINK, Acc. No.: 54 988 59) - SM54.21-D-0140SG

Code Signal Acquisition And Actuation Module (Code: Vs3WABLINK, Acc. No.: 54 988 59) - SM54.21-D-0140SG

Model 907 

Operation no. of the operation texts or standard texts and flat rates
Category Op. no. Operation text Time Acc. no. Code
L 02 2443 Operations: Connect/disconnect vehicle diagnosis system 54 988 59 VS3WABLINK
L 02 2445 Operations: Connect/disconnect charger (vehicle diagnosis system connected) 54 988 59 VS3WABLINK
L 02 2444 Operations: Perform SCN coding in control unit (vehicle diagnosis system connected) 54 988 59 VS3WABLINK
  Notes on SCN coding of control units   AH54.21-P-0004-01X
INSPECT Check     
1 Check whether vehicle is affected by measure. Affected vehicles: Code signal acquisition and actuation module (Code: VS3WABLINK, acc. no.: 54 988 59)
Model 907.### ## as of 000264 up to 002384
SM54.21-D-0140-01AAA 
    IMPORTANT For authorized Mercedes-Benz service partners, only the entry in the Extended VEGA Application (EVA) edition, in the "Current" tab is decisive. An additional test of the affected vehicles in the workshop information system (WIS) or vehicle list is thereby not necessary. SM54.21-D-0140-01AAB
  SCN coding     
2 Connect diagnostic system.    
REFER TO SELF-DIAGNOSTIC SYSTEMS   IMPORTANT Use XENTRY Diagnostics version 05/2018 or higher. The operation steps must be performed exactly as per XENTRY Diagnostics. AD00.00-D-2000-06TS
3 Connect charging equipment.    
REFER TO TESTING & REPAIR Maintaining on-board electrical system voltage
when performing test and diagnosis work on vehicle
NOTES
During the entire work procedure a sufficiently large voltage supply must be provided for the vehicle's on-board electrical system.
Otherwise any undervoltage that occurs may damage the control units.
IMPORTANT Follow the operating instructions for the charger.
IMPORTANT Use the charger to ensure that an adequate power supply (min. 12.5 V) is provided for the on-board electrical system battery.
AR54.10-D-1127TS
4 Perform SCN coding in the signal acquisition and actuation module (SAM). IMPORTANT See process description in diagnostic system "INFO".  
5 Disconnect diagnostic system.    
REFER TO SELF-DIAGNOSTIC SYSTEMS     AD00.00-D-2000-06TS
6 Remove charger from vehicle.    
REFER TO TESTING & REPAIR     AR54.10-D-1127TS