Signal List, Caravan Control Unit, Heating System, Function - GF54.21-D-5057TSA
Model 907
with code JA3 (Intelligent body control.)
SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS
| Signal ID | Signal type/number | Signal: Name/function | Parameter | |
|---|---|---|---|---|
| Byte | Bit | |||
| 01AH | 1 | 0 | Name: Alde_ActualTemp_Zone1_Rq Function: Alde actual temp zone 1 |
File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMPJNVALID/Temperature is invalid |
| 2 | 0 | Name: Alde_Actual_Temp_Zone2_Rq Function: Alde actual temp zone 2 |
File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMPJNVALID/Temperature is invalid |
|
| 3 | 0 | Name: Alde_ActualTemp_OutDr_Snsr_Rq Function: Alde_ActualTemp_OutDr_Snsr |
File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMPJNVALID/Temperature is invalid |
|
| 4 | 0 | Name: Alde_Zone1ActTargTemp_Rq Function: Alde_Zone1ActTargTemp |
File type: 06_Alde_TrgTemp Value/range/increment: 0...50/5...30 °C/0.5 °C Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5 60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C 61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 63/TEMPJNVAUD/Temperature is invalid |
|
| 4 | 6 | Name: Alde_GasSetting_Rq Function: Gas setting |
File type: 01_Alde_GasSetting Value/name/function: 0/OFF/OFF 1/ON/ON |
|
| 4 | 7 | Name: Alde_Priority_El_Gas_Rq Function: Current/gas priority |
File type: 01_Alde_Priority_El_Gas Value/name/function: 0/Prio_Electricity/Priority Electricity 1/Prio_Gas/Priority Gas |
|
| 5 | 0 | Name: Alde_Zone2ActTargTemp_Rq Function: Zone 2 active target temperature |
File type: 06_Alde_TrgTemp Value/range/increment: 0....50/5...30 °C/0.5 °C Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5 60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C 61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 63/TEMPJNVAUD/Temperature is invalid |
|
| 5 | 6 | Name: Alde_ElectricitySetting_Rq Function: Current setting |
File type: 02_Alde_ElectricitySetting Value/name/function: 0/OFF/OFF Value/range/increment: 1/kW 1/1 kW 2/kW 2/2 kW 3/kW_3/3 kW |
|
| 01AH | 6 | 0 | Name: Alde_Panel_Stat_Rq Function: Panel ON/OFF |
File type: 01_Alde_Panel_Stat Value/name/function: 0/OFF/OFF 1/ON/ON |
| 6 | 1 | Name: Alde_Panel_Busy_Rq Function: Alde panel busy. |
File type: 01_Alde_Panel_Busy Value/name/function: 0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master 1/Ignore_sent_sett/Alde panel is busy and will ignore sent settings |
|
| 6 | 2 | Name: Alde_Error_Rq Function: At least one error is active in the Alde panel. |
File type: 01_Alde_Error Value/name/function: 0/No_Error/No error 1/Error_active/At least one error is active |
|
| 6 | 3 | Name: Alde_HotWaterSetting_Rq Function: Hot water setting |
File type: 02_Alde_HotWaterSetting Value/name/function: 0/OFF/OFF 1/normal/normal 2/boost/boost |
|
| 6 | 5 | Name: Alde_ACInstall_Info_Rq Function: Information on installation of AC in Alde system |
File type: 01_Alde_ACInstall_Info Value/name/function: 0/Not_Installed/Truma AC is not installed 1/Installed/Truma AC installed |
|
| 6 | 6 | Name: Alde_ACCSetting_Rq Function: ACC setting |
File type: 01_Alde_ACCSetting Value/name/function: 0/OFF/OFF 1/ON/ON |
|
| 6 | 7 | Name: Alde_PumpRunning_Rq Function: Pump running. |
File type: 01_Alde_PumpRunning Value/name/function: 0/Not_Running/Pump not running1 1/Running/Pump is running |
|
| 7 | 0 | Name: Alde_Rsrv1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: Alde_Rsrv2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 03CH | 1 | 0 | Name: MasterReqB0 | Value/function: 0/SLEEP MODE COMMAND 1/DIAGNOSTIC ADDRESS 'HEATING TRUMA' (1h) 2/DIAGNOSTIC ADDRESS 'SRV' (2h) 3/DIAGNOSTIC ADDRESS 'AACDometic' (3h) 5/DIAGNOSTIC ADDRESS 'BSH' (5h) 6/DIAGNOSTIC ADDRESS 'LRD' (6h) 8/DIAGNOSTIC ADDRESS 'THETFORD' (8h) 16/DIAGNOSTIC ADDRESS 'HEATING ALDE' (10h) 25/DIAGNOSTIC ADDRESS 'SAT' (19h) |
| 2 | 0 | Name: MasterReqB1 | - | |
| 3 | 0 | Name: MasterReqB2 | - | |
| 4 | 0 | Name: MasterReqB3 | - | |
| 5 | 0 | Name: MasterReqB4 | - | |
| 6 | 0 | Name: MasterReqB5 | - | |
| 7 | 0 | Name: MasterReqB6 | - | |
| 8 | 0 | Name: MasterReqB7 | - | |
| 01BH | 1 | 0 | Name: Alde_ActualTemp_Zone1_Rs Function: Alde actual temp zone 1 | File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMP_INVALID/Temperature is invalid |
| 2 | 0 | Name: Alde_ActualTemp_Zone2_Rs Function: Alde actual temp zone 2 |
File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMP_INVALID/Temperature is invalid |
|
| 3 | 0 | Name: Alde_ActualTemp_OutDr_Snsr_Rs Function: Alde_ActualTemp_OutDr_Snsr_Rs |
File type: 08_Alde_ActualTemp Value/range/increment: 0...250/-42...83 °C/0.5 °C Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42 252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C 253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 255/TEMPJNVALID/Temperature is invalid |
|
| 4 | 0 | Name: Alde_Zone1ActTargTemp_Rs Function: Alde_Zone1ActTargTemp_Rs |
File type: 06_Alde_TrgTemp Value/range/increment: 0...50/5...30 °C/0.5 °C Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5 60/POS_TEMP/Out of Range, positiveTemperature is above 50 °C. 61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 63/TEMPJNVAUD/Temperature is invalid |
|
| 4 | 6 | Name: Alde_GasSetting_Rs Function: Gas setting |
File type: 01_Alde_GasSetting Value/name/function: 0/OFF/OFF 1/ON/ON |
|
| 4 | 7 | Name: Alde_Priority_El_Gas_Rs Function: Current/gas priority |
File type: 01_Alde_Priority_El_Gas Value/name/function: 0/Prio_Electricity/Priority Electricity 1/Prio_Gas/Priority Gas |
|
| 5 | 0 | Name: Alde_Zone2ActTargTemp_Rs Function: Zone 2 active target temperature |
File type: 06_Alde_TrgTemp Value/range/increment: 0...50/5...30 °C/0.5 °C Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5 60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C 61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed 62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid 63/TEMPJNVAUD/Temperature is invalid |
|
| 5 | 6 | Name: Alde_ElectricitySetting_Rs Function: Current setting |
File type: 02_Alde_ElectricitySetting Value/name/function: 0/OFF/OFF Value/range/increment: 1/kW 1/1 kW 2/kW_2/2 kW 3/kW 3/3 kW |
|
| 6 | 0 | Name: Alde_Panel_Stat_Rs Function: Panel ON/OFF |
File type: 01_Alde_Panel_Stat Value/name/function: 0/OFF/OFF 1/ON/ON 0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master |
|
| 6 | 1 | Name: Alde_Panel_Busy_Rs Function: Alde panel busy. |
File type: 01_Alde_Panel_Busy Value/name/function: 0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master 1/Ignore_sent_sett/Alde panel is busy and will ignore sent settings |
|
| 6 | 2 | Name: RsErr_HAlde Function: At least one error is active in the Alde panel. |
File type: 01_Alde_Error Value/name/function: 0/No_Error/No error 1/Error_active/At least one error is active |
|
| 6 | 3 | Name: Alde_HotWaterSetting_Rs Function: Hot water setting |
File type: 02_Alde_HotWaterSetting Value/name/function: 0/OFF/OFF 1/normal/normal 2/boost/boost effect |
|
| 6 | 5 | Name: Alde_ACInstall_Info_Rs Function: Information on installation of AC in Alde system |
File type: 01_Alde_ACInstall_Info Value/name/function: 0/Not_Installed/Truma AC is not installed 1/Installed/Truma AC installed |
|
| 6 | 6 | Name: Alde_ACCSetting_Rs Function: ACC setting |
File type: 01_Alde_ACCSetting Value/name/function: 0/OFF/OFF 1/ON/ON |
|
| 6 | 7 | Name: Alde_PumpRunning_Rs Function: Pump running. |
File type: 01_Alde_PumpRunning Value/name/function: 0/Not_Running/Pump not running1 0/Not_Running/Pump/not running1 1/Running/Pump is running |
|
| 7 | 0 | Name: Alde_Rsrv1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: Alde_Rsrv2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 03DH | 1 | 0 | SlaveRespB0 | Value/function: 16/DIAGNOSTIC ADDRESS 'HEATING_ALDE' (10h) |
| 2 | 0 | SlaveRespB1 | - | |
| 3 | 0 | SlaveRespB2 | - | |
| 4 | 0 | SlaveRespB3 | - | |
| 5 | 0 | SlaveRespB4 | - | |
| 6 | 0 | SlaveRespB5 | - | |
| 7 | 0 | SlaveRespB6 | - | |
| 8 | 0 | SlaveRespB7 | - | |
SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS
| Signal ID | Signal type/number | Signal: Name/function | Parameter | |
|---|---|---|---|---|
| Byte | Bit | |||
| 038h | 1 | 0 | Name: HeatingTruma_TargWaterTemp_Rs Function: Target water temperature |
File type: 16_HeatingTruma_TargWaterTemp Value/range/increment: 0...3330/-273...60 °C/0.1 °C |
| 3 | 0 | Name: HeatingTruma_EnergySel_Rs Function: Energy selection |
File type: 08_HeatingTruma_EnergySel Value/name/function: 1/fuel/fuel 2/electricity/electricity 3/both/both (prio electro) |
|
| 4 | 0 | Name: HeatingTruma_PowerLimit_Rs Function: Power limit |
File type: 16_HeatingTruma_PowerLimit Value/range/increment: 900...1800/900...1800 W/1 W |
|
| 6 | 0 | Name: HeatingTruma_FrostControl Function: Truma frost control heater |
File type: DC_BOOL | |
| 6 | 1 | Name: HeatingTruma_230V_Avail Function: 230 V available |
File type: 01_HeatingTruma_230V_Avail Value/name/function: 0/NOT_AVAILABLE/Automatic mode not available 1/AVAILABLE/Automatic mode available |
|
| 6 | 2 | Name: HeatingTruma_WindowSwitch Function: Truma window switch heater |
File type: DC_BOOL | |
| 6 | 3 | Name: HeatingTruma_ManualMode Function: Truma heater manual mode |
File type: 01_HeatingTruma_ManualMode Value/name/function: 0/OFF/Manual mode OFF 1/ON/Manual mode ON |
|
| 6 | 4 | Name: HeatingTruma_RFU6 Function: Reserved for future use. |
File type: Rsrv02 | |
| 6 | 6 | Name: RsErr_HeatingTruma Function: Response error |
File type: DC_BOOL | |
| 038h | 6 | 7 | Name: HeatingTruma_CombiError Function: Truma heater combi error |
File type: DC_BOOL |
| 7 | 0 | Name: HeatingTruma_RFU1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: HeatingTruma_RFU2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 03AH | 1 | 0 | Name: HeatingTruma_TargAirTemp_Rs Function: Target air temperature |
File type: 12_HeatingTruma_TargAirTemp Value/range/increment: 0...3030/-273...30 °C/0.1 °C |
| 2 | 4 | Name: HeatingTruma_Mode_Rs Function: Mode |
File type: 04_HeatingTruma_Mode Value/name/function: 0/Normal/Normal 1/Automatic/Automatic |
|
| 3 | 0 | Name: HeatingTruma_RFU1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 4 | 0 | Name: HeatingTruma_RFU2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 5 | 0 | Name: HeatingTruma_EnergySel_Rs Function: Energy selection |
File type: 08_HeatingTruma_EnergySel Value/name/function: 1/fuel/fuel 2/electricity/electricity 3/both/both (prio electro) |
|
| 6 | 0 | Name: HeatingTruma_RFU3 Function: Reserved for future use. |
File type: Rsrv08 | |
| 7 | 0 | Name: HeatingTruma_RFU4 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: HeatingTruma_RFU5 Function: Reserved for future use. |
File type: Rsrv08 | |
| 03DH | 1 | 0 | Name: SlaveRespB0 | Value/function: 1/DIAGNOSTIC ADDRESS 'HEATING_TRUMA' (1h) |
| 2 | 0 | Name: SlaveRespB1 | - | |
| 3 | 0 | Name: SlaveRespB2 | - | |
| 4 | 0 | Name: SlaveRespB3 | - | |
| 5 | 0 | Name: SlaveRespB4 | - | |
| 6 | 0 | Name: SlaveRespB5 | - | |
| 7 | 0 | Name: SlaveRespB6 | - | |
| 8 | 0 | Name: SlaveRespB7 | - | |
SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS
| Signal ID | Signal type/number | Signal: Name/function | Parameter | |
|---|---|---|---|---|
| Byte | Bit | |||
| 00CH | 4 | 0 | Name: Thetford_Warn_Error_Info Function: Thetford warning/error information |
File type: 08_Thetford_Warn_Error_Info Value/name/function: 0/No_Error/No error 1/GasHeater_ON_when_not_expected/Gas Heater ON when not expected 2/Incorrect_Feedback_from_BCM/Incorrect Feedback from BCM 3/Gas_Heater_in_Lockout/Gas heater in lockout 4/DC_Heater_Failed/DC heater failed 5/DCHeater_ON_when_not_expected/DC heater ON when not expected 6/DC_Voltage_out_of_bounds/DC voltage out of bounds 7/No_Dplus_Signal/No D+ signal (no DC heater allowed) 8/ACHeater_Failed/AC heater failed 9/ACHeater_ON_when_not_expected/AC heater ON when not expected 10/ACVoltage_out_of_bounds/AC voltage out of bounds 11/AUTO_Mode/In AUTO mode, no power source available 12/No_Communication/No communication 13/No_Thermistor/No thermistor (in BOS mode) 106/DCVoltage_out_of_bounds/DC voltage out of bounds |
| 5 | 0 | Name: Thetford_ACVoltage Function: Thetford AC voltage |
File type: 08_Thetford_ACVoltage Value/range/increment: 0...255/0...255 V/1 V |
|
| 6 | 0 | Name: Thetford_DCVoltage Function: Thetford DC voltage |
File type: 08_Thetford_DCVoltage Value/range/increment: 0...255/0...25,500 mV/100 mV |
|
| 7 | 0 | Name: Function: | - | |
| 8 | 0 | Name: Function: | - | |
| 8 | 7 | Name: RsErr_Thetford Function: Response error |
File type: DC_BOOL | |
| 03DH | 1 | 0 | Name: SlaveRespB0 Function: |
Value/function: 8/DIAGNOSTIC ADDRESS 'THETFORD' (8h) |
| 2 | 0 | Name: SlaveRespB1 Function: |
- | |
| 3 | 0 | Name: SlaveRespB2 Function: |
- | |
| 03DH | 4 | 0 | Name: SlaveRespB3 Function: |
- |
| 5 | 0 | Name: SlaveRespB4 Function: |
- | |
| 6 | 0 | Name: SlaveRespB5 Function: |
- | |
| 7 | 0 | Name: SlaveRespB6 Function: |
- | |
| 8 | 0 | Name: SlaveRespB7 Function: |
- | |
| 037h | 1 | 0 | Name: HeatingTruma_TargWaterTemp_Rq Function: Target water temperature |
File type: 16_HeatingTruma_TargWaterTemp Value/range/increment: 0...3330/-273...60 °C/0.1 °C |
| 3 | 0 | Name: HeatingTruma_EnergySel_Rq Function: Energy selection |
File type: 08_HeatingTruma_EnergySel Value/name/function: 1/fuel/fuel 2/electricity/electricity 3/both/both (prio electro) |
|
| 4 | 0 | Name: HeatingTruma_PowerLimit_Rq Function: Power limit |
File type: 16_HeatingTruma_PowerLimit Value/range/increment: 900...1800/900...1800 W/1 W |
|
| 6 | 0 | Name: HeatingTruma_RFU1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 7 | 0 | Name: HeatingTruma_RFU2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: HeatingTruma_RFU3 Function: Reserved for future use. |
File type: Rsrv08 | |
| 039h | 1 | 0 | Name: HeatingTruma_TargAirTemp_Rq Function: Target air temperature |
File type: 12_HeatingTruma_TargAirTemp Value/range/increment: 0...3030/-273...30 °C/0.1 °C |
| 2 | 4 | Name: HeatingTruma_Mode_Rq Function: Mode |
File type: 04_HeatingTruma_Mode Value/name/function: 0/Normal/Normal 1/Automatic/Automatic |
|
| 3 | 0 | Name: HeatingTruma_CompControl Function: Composite control |
File type: 08_HeatingTruma_CompControl | |
| 4 | 0 | Name: HeatingTruma_EnergySel_Rq Function: Energy selection |
Value/name/function: 1/fuel/fuel 2/electricity/electricity 3/both/both (prio electro) |
|
| 5 | 0 | Name: HeatingTruma_RFU1 Function: Reserved for future use. |
File type: Rsrv08 | |
| 6 | 0 | Name: HeatingTruma_RFU2 Function: Reserved for future use. |
File type: Rsrv08 | |
| 7 | 0 | Name: HeatingTruma_RFU3 Function: Reserved for future use. |
File type: Rsrv08 | |
| 8 | 0 | Name: HeatingTruma_RFU4 Function: Reserved for future use. |
File type: Rsrv08 | |