Signal List, Caravan Control Unit, Heating System, Function - GF54.21-D-5057TSA

Model 907 

with code JA3 (Intelligent body control.) 

SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS

Signal ID Signal type/number Signal: Name/function Parameter
  Byte Bit    
01AH 1 0 Name: Alde_ActualTemp_Zone1_Rq
Function: Alde actual temp zone 1
File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMPJNVALID/Temperature is invalid
  2 0 Name: Alde_Actual_Temp_Zone2_Rq
Function: Alde actual temp zone 2
File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMPJNVALID/Temperature is invalid
  3 0 Name: Alde_ActualTemp_OutDr_Snsr_Rq
Function: Alde_ActualTemp_OutDr_Snsr
File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMPJNVALID/Temperature is invalid
  4 0 Name: Alde_Zone1ActTargTemp_Rq
Function: Alde_Zone1ActTargTemp
File type: 06_Alde_TrgTemp
Value/range/increment: 0...50/5...30 °C/0.5 °C
Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5
60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C
61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
63/TEMPJNVAUD/Temperature is invalid
  4 6 Name: Alde_GasSetting_Rq
Function: Gas setting
File type: 01_Alde_GasSetting
Value/name/function: 0/OFF/OFF
1/ON/ON
  4 7 Name: Alde_Priority_El_Gas_Rq
Function: Current/gas priority
File type: 01_Alde_Priority_El_Gas
Value/name/function: 0/Prio_Electricity/Priority Electricity
1/Prio_Gas/Priority Gas
  5 0 Name: Alde_Zone2ActTargTemp_Rq
Function: Zone 2 active target temperature
File type: 06_Alde_TrgTemp
Value/range/increment: 0....50/5...30 °C/0.5 °C
Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5
60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C
61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
63/TEMPJNVAUD/Temperature is invalid
  5 6 Name: Alde_ElectricitySetting_Rq
Function: Current setting
File type: 02_Alde_ElectricitySetting
Value/name/function: 0/OFF/OFF
Value/range/increment: 1/kW 1/1 kW
2/kW 2/2 kW
3/kW_3/3 kW
01AH 6 0 Name: Alde_Panel_Stat_Rq
Function: Panel ON/OFF
File type: 01_Alde_Panel_Stat
Value/name/function: 0/OFF/OFF
1/ON/ON
  6 1 Name: Alde_Panel_Busy_Rq
Function: Alde panel busy.
File type: 01_Alde_Panel_Busy
Value/name/function: 0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master
1/Ignore_sent_sett/Alde panel is busy and will ignore sent settings
  6 2 Name: Alde_Error_Rq
Function: At least one error is active in the Alde panel.
File type: 01_Alde_Error
Value/name/function: 0/No_Error/No error
1/Error_active/At least one error is active
  6 3 Name: Alde_HotWaterSetting_Rq
Function: Hot water setting
File type: 02_Alde_HotWaterSetting
Value/name/function: 0/OFF/OFF
1/normal/normal
2/boost/boost
  6 5 Name: Alde_ACInstall_Info_Rq
Function: Information on installation of AC in Alde system
File type: 01_Alde_ACInstall_Info
Value/name/function: 0/Not_Installed/Truma AC is not installed
1/Installed/Truma AC installed
  6 6 Name: Alde_ACCSetting_Rq
Function: ACC setting
File type: 01_Alde_ACCSetting
Value/name/function: 0/OFF/OFF
1/ON/ON
  6 7 Name: Alde_PumpRunning_Rq
Function: Pump running.
File type: 01_Alde_PumpRunning
Value/name/function: 0/Not_Running/Pump not running1
1/Running/Pump is running
  7 0 Name: Alde_Rsrv1
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: Alde_Rsrv2
Function: Reserved for future use.
File type: Rsrv08
03CH 1 0 Name: MasterReqB0 Value/function: 0/SLEEP MODE COMMAND
1/DIAGNOSTIC ADDRESS 'HEATING TRUMA' (1h)
2/DIAGNOSTIC ADDRESS 'SRV' (2h)
3/DIAGNOSTIC ADDRESS 'AACDometic' (3h) 5/DIAGNOSTIC ADDRESS 'BSH' (5h)
6/DIAGNOSTIC ADDRESS 'LRD' (6h)
8/DIAGNOSTIC ADDRESS 'THETFORD' (8h)
16/DIAGNOSTIC ADDRESS 'HEATING ALDE' (10h)
25/DIAGNOSTIC ADDRESS 'SAT' (19h)
  2 0 Name: MasterReqB1 -
  3 0 Name: MasterReqB2 -
  4 0 Name: MasterReqB3 -
  5 0 Name: MasterReqB4 -
  6 0 Name: MasterReqB5 -
  7 0 Name: MasterReqB6 -
  8 0 Name: MasterReqB7 -
01BH 1 0 Name: Alde_ActualTemp_Zone1_Rs Function: Alde actual temp zone 1 File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMP_INVALID/Temperature is invalid
  2 0 Name: Alde_ActualTemp_Zone2_Rs
Function: Alde actual temp zone 2
File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMP_INVALID/Temperature is invalid
  3 0 Name: Alde_ActualTemp_OutDr_Snsr_Rs
Function: Alde_ActualTemp_OutDr_Snsr_Rs
File type: 08_Alde_ActualTemp
Value/range/increment: 0...250/-42...83 °C/0.5 °C
Value/name/function: 251/NEG_TEMP/Out of Range, Negative. Temperature is below -42
252/POS_TEMP/Out of Range, positive. Temperature is above 83 °C
253/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
254/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
255/TEMPJNVALID/Temperature is invalid
  4 0 Name: Alde_Zone1ActTargTemp_Rs
Function: Alde_Zone1ActTargTemp_Rs
File type: 06_Alde_TrgTemp
Value/range/increment: 0...50/5...30 °C/0.5 °C
Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5
60/POS_TEMP/Out of Range, positiveTemperature is above 50 °C.
61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
63/TEMPJNVAUD/Temperature is invalid
  4 6 Name: Alde_GasSetting_Rs
Function: Gas setting
File type: 01_Alde_GasSetting
Value/name/function: 0/OFF/OFF
1/ON/ON
  4 7 Name: Alde_Priority_El_Gas_Rs
Function: Current/gas priority
File type: 01_Alde_Priority_El_Gas
Value/name/function: 0/Prio_Electricity/Priority Electricity
1/Prio_Gas/Priority Gas
  5 0 Name: Alde_Zone2ActTargTemp_Rs
Function: Zone 2 active target temperature
File type: 06_Alde_TrgTemp
Value/range/increment: 0...50/5...30 °C/0.5 °C
Value/name/function: 59/NEG_TEMP/Out of Range, Negative. Temperature is below 5
60/POS_TEMP/Out of Range, positive. Temperature is above 50 °C
61/TEMP_SENSOR_NOT_INSTLD/Temperature sensor not installed
62/TEMP_SENSOR_INVALID/Marks that the temperature sensor is not yet implemented and the temperature is invalid
63/TEMPJNVAUD/Temperature is invalid
  5 6 Name: Alde_ElectricitySetting_Rs
Function: Current setting
File type: 02_Alde_ElectricitySetting
Value/name/function: 0/OFF/OFF
Value/range/increment: 1/kW 1/1 kW
2/kW_2/2 kW
3/kW 3/3 kW
  6 0 Name: Alde_Panel_Stat_Rs
Function: Panel ON/OFF
File type: 01_Alde_Panel_Stat
Value/name/function: 0/OFF/OFF
1/ON/ON
0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master
  6 1 Name: Alde_Panel_Busy_Rs
Function: Alde panel busy.
File type: 01_Alde_Panel_Busy
Value/name/function: 0/Apply_sent_sett/Alde panel will apply sent settings from CI-bus master
1/Ignore_sent_sett/Alde panel is busy and will ignore sent settings
  6 2 Name: RsErr_HAlde
Function: At least one error is active in the Alde panel.
File type: 01_Alde_Error
Value/name/function: 0/No_Error/No error
1/Error_active/At least one error is active
  6 3 Name: Alde_HotWaterSetting_Rs
Function: Hot water setting
File type: 02_Alde_HotWaterSetting
Value/name/function: 0/OFF/OFF
1/normal/normal
2/boost/boost effect
  6 5 Name: Alde_ACInstall_Info_Rs
Function: Information on installation of AC in Alde system
File type: 01_Alde_ACInstall_Info
Value/name/function: 0/Not_Installed/Truma AC is not installed
1/Installed/Truma AC installed
  6 6 Name: Alde_ACCSetting_Rs
Function: ACC setting
File type: 01_Alde_ACCSetting
Value/name/function: 0/OFF/OFF
1/ON/ON
  6 7 Name: Alde_PumpRunning_Rs
Function: Pump running.
File type: 01_Alde_PumpRunning
Value/name/function: 0/Not_Running/Pump not running1
0/Not_Running/Pump/not running1
1/Running/Pump is running
  7 0 Name: Alde_Rsrv1
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: Alde_Rsrv2
Function: Reserved for future use.
File type: Rsrv08
03DH 1 0 SlaveRespB0 Value/function: 16/DIAGNOSTIC ADDRESS 'HEATING_ALDE' (10h)
  2 0 SlaveRespB1 -
  3 0 SlaveRespB2 -
  4 0 SlaveRespB3 -
  5 0 SlaveRespB4 -
  6 0 SlaveRespB5 -
  7 0 SlaveRespB6 -
  8 0 SlaveRespB7 -
SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS

Signal ID Signal type/number Signal: Name/function Parameter
  Byte Bit    
038h 1 0 Name: HeatingTruma_TargWaterTemp_Rs
Function: Target water temperature
File type: 16_HeatingTruma_TargWaterTemp
Value/range/increment: 0...3330/-273...60 °C/0.1 °C
  3 0 Name: HeatingTruma_EnergySel_Rs
Function: Energy selection
File type: 08_HeatingTruma_EnergySel
Value/name/function: 1/fuel/fuel
2/electricity/electricity
3/both/both (prio electro)
  4 0 Name: HeatingTruma_PowerLimit_Rs
Function: Power limit
File type: 16_HeatingTruma_PowerLimit
Value/range/increment: 900...1800/900...1800 W/1 W
  6 0 Name: HeatingTruma_FrostControl
Function: Truma frost control heater
File type: DC_BOOL
  6 1 Name: HeatingTruma_230V_Avail
Function: 230 V available
File type: 01_HeatingTruma_230V_Avail
Value/name/function: 0/NOT_AVAILABLE/Automatic mode not available
1/AVAILABLE/Automatic mode available
  6 2 Name: HeatingTruma_WindowSwitch
Function: Truma window switch heater
File type: DC_BOOL
  6 3 Name: HeatingTruma_ManualMode
Function: Truma heater manual mode
File type: 01_HeatingTruma_ManualMode
Value/name/function: 0/OFF/Manual mode OFF
1/ON/Manual mode ON
  6 4 Name: HeatingTruma_RFU6
Function: Reserved for future use.
File type: Rsrv02
  6 6 Name: RsErr_HeatingTruma
Function: Response error
File type: DC_BOOL
038h 6 7 Name: HeatingTruma_CombiError
Function: Truma heater combi error
File type: DC_BOOL
  7 0 Name: HeatingTruma_RFU1
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: HeatingTruma_RFU2
Function: Reserved for future use.
File type: Rsrv08
03AH 1 0 Name: HeatingTruma_TargAirTemp_Rs
Function: Target air temperature
File type: 12_HeatingTruma_TargAirTemp
Value/range/increment: 0...3030/-273...30 °C/0.1 °C
  2 4 Name: HeatingTruma_Mode_Rs
Function: Mode
File type: 04_HeatingTruma_Mode
Value/name/function: 0/Normal/Normal
1/Automatic/Automatic
  3 0 Name: HeatingTruma_RFU1
Function: Reserved for future use.
File type: Rsrv08
  4 0 Name: HeatingTruma_RFU2
Function: Reserved for future use.
File type: Rsrv08
  5 0 Name: HeatingTruma_EnergySel_Rs
Function: Energy selection
File type: 08_HeatingTruma_EnergySel
Value/name/function: 1/fuel/fuel
2/electricity/electricity
3/both/both (prio electro)
  6 0 Name: HeatingTruma_RFU3
Function: Reserved for future use.
File type: Rsrv08
  7 0 Name: HeatingTruma_RFU4
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: HeatingTruma_RFU5
Function: Reserved for future use.
File type: Rsrv08
03DH 1 0 Name: SlaveRespB0 Value/function: 1/DIAGNOSTIC ADDRESS 'HEATING_TRUMA' (1h)
  2 0 Name: SlaveRespB1 -
  3 0 Name: SlaveRespB2 -
  4 0 Name: SlaveRespB3 -
  5 0 Name: SlaveRespB4 -
  6 0 Name: SlaveRespB5 -
  7 0 Name: SlaveRespB6 -
  8 0 Name: SlaveRespB7 -
SIGNAL LIST FOR HEATING SYSTEM LIN CONNECTIONS

Signal ID Signal type/number Signal: Name/function Parameter
  Byte Bit    
00CH 4 0 Name: Thetford_Warn_Error_Info
Function: Thetford warning/error information
File type: 08_Thetford_Warn_Error_Info
Value/name/function: 0/No_Error/No error
1/GasHeater_ON_when_not_expected/Gas Heater ON when not expected
2/Incorrect_Feedback_from_BCM/Incorrect Feedback from BCM
3/Gas_Heater_in_Lockout/Gas heater in lockout
4/DC_Heater_Failed/DC heater failed
5/DCHeater_ON_when_not_expected/DC heater ON when not expected
6/DC_Voltage_out_of_bounds/DC voltage out of bounds
7/No_Dplus_Signal/No D+ signal (no DC heater allowed)
8/ACHeater_Failed/AC heater failed
9/ACHeater_ON_when_not_expected/AC heater ON when not expected
10/ACVoltage_out_of_bounds/AC voltage out of bounds
11/AUTO_Mode/In AUTO mode, no power source available
12/No_Communication/No communication
13/No_Thermistor/No thermistor (in BOS mode)
106/DCVoltage_out_of_bounds/DC voltage out of bounds
  5 0 Name: Thetford_ACVoltage
Function: Thetford AC voltage
File type: 08_Thetford_ACVoltage
Value/range/increment: 0...255/0...255 V/1 V
  6 0 Name: Thetford_DCVoltage
Function: Thetford DC voltage
File type: 08_Thetford_DCVoltage
Value/range/increment: 0...255/0...25,500 mV/100 mV
  7 0 Name: Function: -
  8 0 Name: Function: -
  8 7 Name: RsErr_Thetford
Function: Response error
File type: DC_BOOL
03DH 1 0 Name: SlaveRespB0
Function:
Value/function: 8/DIAGNOSTIC ADDRESS 'THETFORD' (8h)
  2 0 Name: SlaveRespB1
Function:
-
  3 0 Name: SlaveRespB2
Function:
-
03DH 4 0 Name: SlaveRespB3
Function:
-
  5 0 Name: SlaveRespB4
Function:
-
  6 0 Name: SlaveRespB5
Function:
-
  7 0 Name: SlaveRespB6
Function:
-
  8 0 Name: SlaveRespB7
Function:
-
037h 1 0 Name: HeatingTruma_TargWaterTemp_Rq
Function: Target water temperature
File type: 16_HeatingTruma_TargWaterTemp
Value/range/increment: 0...3330/-273...60 °C/0.1 °C
  3 0 Name: HeatingTruma_EnergySel_Rq
Function: Energy selection
File type: 08_HeatingTruma_EnergySel
Value/name/function: 1/fuel/fuel
2/electricity/electricity
3/both/both (prio electro)
  4 0 Name: HeatingTruma_PowerLimit_Rq
Function: Power limit
File type: 16_HeatingTruma_PowerLimit
Value/range/increment: 900...1800/900...1800 W/1 W
  6 0 Name: HeatingTruma_RFU1
Function: Reserved for future use.
File type: Rsrv08
  7 0 Name: HeatingTruma_RFU2
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: HeatingTruma_RFU3
Function: Reserved for future use.
File type: Rsrv08
039h 1 0 Name: HeatingTruma_TargAirTemp_Rq
Function: Target air temperature
File type: 12_HeatingTruma_TargAirTemp
Value/range/increment: 0...3030/-273...30 °C/0.1 °C
  2 4 Name: HeatingTruma_Mode_Rq
Function: Mode
File type: 04_HeatingTruma_Mode
Value/name/function: 0/Normal/Normal
1/Automatic/Automatic
  3 0 Name: HeatingTruma_CompControl
Function: Composite control
File type: 08_HeatingTruma_CompControl
  4 0 Name: HeatingTruma_EnergySel_Rq
Function: Energy selection
Value/name/function: 1/fuel/fuel
2/electricity/electricity
3/both/both (prio electro)
  5 0 Name: HeatingTruma_RFU1
Function: Reserved for future use.
File type: Rsrv08
  6 0 Name: HeatingTruma_RFU2
Function: Reserved for future use.
File type: Rsrv08
  7 0 Name: HeatingTruma_RFU3
Function: Reserved for future use.
File type: Rsrv08
  8 0 Name: HeatingTruma_RFU4
Function: Reserved for future use.
File type: Rsrv08