PSM Logic Functions, Threshold Switch Function - GF54.21-D-3209TSA

Model 907 

with code ED5 (Parameterisable special module) 

G13792299

Threshold switch, function 

The threshold switch has an analog input (E) with 16 bit width and 4 digital outputs (Aa, Ab , Ac , Ad ). The input (E) is an encodable filter connected in series.

The input value is compared with up to 4 threshold values (A, B, C, D) and then the relevant output set (AA , Ab , Ac , Ad ).

When coding the threshold switch the parameter threshold value (Psa Psb , Psc , Psd ) must match the following coding specification:

Threshold value (A) < Threshold value (B) < Threshold value (C) < Threshold value (D).

If this coding specification is not followed the characteristic of the threshold switch is not defined.

For outputs (AA , Ab , Ac , Ad ) a run point or a bar graph function can be coded.

IMPORTANT Signal identification number = Signal ID.

SEQUENTIAL POINT FUNCTION

Input (E) Output (AA ) Output (AB ) Output (AC ) Output (AD )
Input (E) ← Threshold value (A) 0 0 0 0
Threshold value (A) < Input (E) ← Threshold value (B) 1 0 0 0
Threshold value (B) < Input (E) ← Threshold value (C) 0 1 0 0
Threshold value (C) < Input (E) ← Threshold value (D) 0 0 1 0
Threshold value (D) < Input (E) 0 0 0 1
BAR GRAPH FUNCTION

Input (E) Output (AA ) Output (AB ) Output (AC ) Output (AD )
Input (E) ← Threshold value (A) 0 0 0 0
Threshold value (A) < Input (E) ← Threshold value (B) 1 0 0 0
Threshold value (B) < Input (E) ← Threshold value (C) 1 1 0 0
Threshold value (C) < Input (E) ← Threshold value (D) 1 1 1 0
Threshold value (D) < Input (E) 1 1 1 1
CODING VIA DATA ENTRY TABLE

Designation in data entry table Data entry bit width Data bit evaluation Meaning
B1_G1_SS1_threshold_A 16 bit - Encodable threshold value (A)
B1 G1 SS1 threshold B 16 bit - Encodable threshold value (B)
B1_G1_SS1_threshold_C 16 bit - Encodable threshold value (C)
B1_G1_SS1_threshold_D 16 bit - Encodable threshold value (D)
B1_G1_SS1_mode 1 bit   Adjustment value:
Bar graph → 0 Sequential point → 1
B1_G1_SS1_signal_ID 32 bit 16 bit Filter + signal-ID input signal data entry
SIGNAL ID OF OUTPUTS

Designation in signal ID list Data bit width Meaning
Out_G1_SS1_A 1 bit Signal ID of output (AA )
Out_G1_SS1_B 1 bit Signal-ID of output (AB )
Out_G1_SS1_C 1 bit Signal-ID of output (AC )
Out_G1_SS1_D 1 bit Signal-ID of output (AD )

The same applies for the other threshold switches with the naming conventions:

Overview of system components for parameterizable special module (PSM) GF54.21-D-9998TSA