PSM Logic Functions, Hysteresis Block Function - GF54.21-D-3208TSA

Model 907 

with code ED5 (Parameterisable special module) 

G13792298

Hysteresis block, function, general 

The input (E) of the hysteresis block is 16 bits wide. Output (AA ) and output (AB ) are digital (binary), whereby output (AB ) always represents the inversion of output (Aa).

A codable input filter is connected upstream of the input (E) of the hysteresis block.

Using the hysteresis block, it is possible to e.g. convert an analog signal into a digital signal using a threshold switch.

Coding of hysteresis block 

The lower threshold parameter (low) (PSU ) and the upper threshold parameter (high) (PSO ) can be coded using the data entry table.

No behavior is defined for lower threshold parameter (low) (PSu ) > upper threshold parameter (high) (PSo ).

IMPORTANT Signal identification number = Signal ID.

CODING VIA DATA ENTRY TABLE

Designation in data entry table Data entry bit width Data bit evaluation Meaning
B1_G1_HB1_signal_ID 32 bit 16 bit Filter + signal-ID input signal data entry
B1_G1_HB1_threshold_low 16 bit - Lower threshold parameter (low) (PSU )
B1_G1_HB1_threshold_high 16 bit - Upper threshold parameter (high) (Pso )
SIGNAL ID OF OUTPUTS

Designation in signal ID list Data bit width Meaning
Out_G1_HB 1 bit Signal ID for output (AA )
Out_G1_HB_inv 1 bit Signal ID for inverted output (A B )

The same applies for the other hysteresis blocks under observation of the naming conventions:

Overview of system components for parameterizable special module (PSM) GF54.21-D-9998TSA