PSM Logic Functions, Constants Function - GF54.21-D-3215TSA
Model 907
with code ED5 (Parameterisable special module)
Constants function
A constant has a 16-bit output and no input. Its content is adjusted and coded using the data entry table.
Signal identification number = Signal ID.
With the signal ID, the constant can be used like a signal from the signal pool.
CODING VIA DATA ENTRY TABLE
| Designation in data entry table | Data entry bit width | Meaning |
|---|---|---|
| B1_G1_K1_value | 16 bit | Signal ID of the source of the constant value |
| B1_G1_K2_value | 16 bit | Signal ID of the source of the constant value |
| B1_G1_K3_value | 16 bit | Signal ID of the source of the constant value |
| B1_G1_K4_value | 16 bit | Signal ID of the source of the constant value |
| B1_G1_K5_value | 16 bit | Signal ID of the source of the constant value |
SIGNAL ID OF OUTPUTS
| Designation in signal ID list | Data bit width | Meaning |
|---|---|---|
| Out_G1_K1_value | 16 bit | Signal ID for constant 1 |
| Out_G1_K2_value | 16 bit | Signal ID for constant 2 |
| Out_G1_K3_value | 16 bit | Signal ID for constant 3 |
| Out_G1_K4_value | 16 bit | Signal ID for constant 4 |
| Out_G1_K5_value | 16 bit | Signal ID for constant 5 |
The same applies for the other constants, taking into account the naming conventions:
- "B<block number>_G<group number>_K<number>_Value"
- "Out_G<group number>_K<number>_Value"
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |