Manually Release Pressure In Hydraulic System Of Electrohydraulic Suspension With Defective Shutoff Valve - AR32.50-P-0015-02S
Model 223
with code 490 (Electrohydraulic suspension)
| Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure. Risk of poisoning from swallowing hydraulic fluid. | Depressurize hydraulic system completely before starting any work on it. Wear protective clothing and safety glasses. | AS00.00-Z-0013-01A | |
| Topical note | Information on E-ACTIVE BODY CONTROL suspension | AH32.50-P-0002-01ME | |
| Notes on safety-relevant components | AH00.00-Z-0019-01A | ||
| 000 588 03 82 00 Filling unit | WS32.00-P-0032B |
- Connect return hose of filling unit to connection fitting (4) and release pressure in system.
If the shutoff valves (2, 3) are not closed, hydraulic pressure will escape from the suspension strut (1). It is not possible to fill the suspension strut (1).
The suspension strut (1) must be replaced.
- Remove return hose of filling unit from connection fitting (4).
- Connect return hose of filling unit to connection fitting (5) and release pressure in system.
- Remove return hose of filling unit from connection fitting (5).