Signal List, Caravan Control Unit, Refrigerator, Function - GF54.21-D-5059TSA

Model 447 

with code JA3 (Intelligent body control.) 

with code XM7 (MOPF II) 

Model 907, 910 

with code JA3 (Intelligent body control.) 

SIGNAL LIST FOR REFRIGERATOR LIN CONNECTIONS

Signal ID Type/number Signal name Function File type Value Name/range Setting/Increment
  Byte Bit            
00Bh 1 0 Thetford_AbsrbFridge_Rq Refrigerator noise damper ON/OFF 01_Thetford_AbsrbFridge 0 OFF OFF
            1 ON ON
  1 1 Thetford_PowerMode Thetford power mode 02_Thetford_PowerMode 0 Automatic_Mode Automatic mode
            1 Manual_AC Manual AC mode
            2 Manual_DC Manual DC mode
            3 Manual_Gas Manual gas mode
  1 3 - - - - - -
  2 0 Thetford_ActualFridgeSetting_Rq Thetford actual fridge setting 04_Thetford_ActualFridgeSet ting - - -
  2 4 Thetford_ActualFreezer Setting_Rq Thetford actual freezer setting 04_Thetford_ActualFreezerSetting - - -
  3 0 Thetford_FrameHeater_Rq Thetford frame heater ON/OFF 01_Thetford_FrameHeater 0 OFF OFF
            1 ON ON
  3 1 Thetford_Fan1_Rq Thetford Blower 1 01_Thetford_Fan1 0 OFF OFF
            1 ON ON
  3 2 Thetford_Fan2_Rq Thetford Blower 2 01_Thetford_Fan2 0 OFF OFF
            1 ON ON
  3 3 Thetford_Buzzer_Rq Thetford buzzer 01_Thetford_Buzzer 0 OFF OFF
            1 ON ON
  3 4 Thetford_Icemaker_Rq Thetford icemaker 01_Thetford_Icemaker 0 OFF OFF
            1 ON ON
  3 5 - - - - - -
  4 0 Thetford_ClockHour Thetford clock, hour 08_Thetford_ClockHour 0...23 0...23 h 1 h
  5 0 Thetford_ClockMinute Thetford clock, minute 08_Thetford_ClockMinute 0...59 0...59 min 1 min
  6 0 - - - - - -
  7 0 - - - - - -
  8 0 - - - - - -
SIGNAL LIST FOR REFRIGERATOR LIN CONNECTIONS

Signal ID Type/number Signal name Function File type Value Name Setting
  By t e B it            
00Ch 1 0 Thetford_AbsrbFridge_Rs Refrigerator noise damper ON/OFF 01_Thetford_AbsrbFridge 0 OFF OFF
            1 ON ON
  1 1 Thetford_PowerSource Thetford power source 02_Thetford_PowerSource 0 NONE None
            1 AC AC
            2 DC DC
            3 GAS GAS
  1 3 Thetford_AutomaticMode Thetford automatic mode 01_Thetford_AutomaticMode 0 Manual Manual
            1 AUTOMATIC Automatic
  1 4 - - - - - -
  2 0 Thetford_ActualFridgeSetting_Rs Thetford actual fridge setting 04_Thetford_ActualFridgeSet ting - - -
  2 4 Thetford_ActualFreezer Setting_Rs Thetford actual freezer setting 04_Thetford_ActualFreezerSetting - - -
  3 0 Thetford_FrameHeater_Rs Thetford frame heater ON/OFF 01_Thetford_FrameHeater 0 OFF OFF
            1 ON ON
  3 1 Thetford_Fan1_Rs Thetford Blower 1 01_Thetford_Fan1 0 OFF OFF
            1 ON ON
  3 2 Thetford_Fan2_Rs Thetford Blower 2 01_Thetford_Fan2 0 OFF OFF
            1 ON ON
  3 3 Thetford_Buzzer_Rs Thetford buzzer 01_Thetford_Buzzer 0 OFF OFF
            1 ON ON
  3 4 Thetford_Icemaker_Rs Thetford icemaker 01_Thetford_Icemaker 0 OFF OFF
            1 ON ON
  3 5 Thetford_Door Open/close door. 01_Thetford_Door 0 CLOSED Door closed
            1 OPEN Door open
  3 6 Thetford_DPlusSignal Thetford D+ signal present 01_Thetford_DPlusSignal 0 Not_Present D+ signal not present
            1 Present D+ signal present