Signal List, Caravan Control Unit, Charger, Function - GF54.21-D-5062TSA
Model 447
with code JA3 (Intelligent body control.)
with code XM7 (MOPF II)
Model 907, 910
with code JA3 (Intelligent body control.)
SIGNAL LIST FOR CHARGER LIN CONNECTIONS
| Signal ID | Type/number | Signal name | Function | File type | Value | Name/range | Setting/Step width | |
|---|---|---|---|---|---|---|---|---|
| Byte | Bit | |||||||
| 018h | 1 | 0 | LRD_ChargVoltage | Charging voltage | 08_LRD_ChargVoltage | - | - | - |
| 2 | 0 | LRD_BattVol_0_7 | Battery voltage 0...7 | 08_LRD_BattVol | - | - | - | |
| 3 | 0 | LRD_BattVol_8_15 | Battery voltage 8...15 | 08_LRD_BattVol | - | - | - | |
| 4 | 0 | LRD_Rsrv | Reserved for future use. | Rsrv08 | - | - | - | |
| 021h | 1 | 0 | RsErr_BSH_IBS | LIN standard flag which indicates that an error occurred during the previous transmission. | 01_BSH_LINRespErr | 0 | FLAG_INACTIVE | Flag inactive |
| 1 | FLAG_ACTIVE | Flag active | ||||||
| 1 | 1 | BSH_WakeupStat | Information as to whether the intelligent battery sensor (IBS) has activated the master or not. | 02_BSH_WakeupStat | 0 | No_Active_Wakeup_Demand | No wake-up query | |
| 1 | Active_Wake-up_Demand | Wake-up query | ||||||
| 2 | Not_defined | Not defined | ||||||
| 1 | 3 | BSH_Event_LowVoltage | Voltage lower than defined level | 01_BSH_Event_LowVoltage | 0 | FLAG_INACTIVE | Flag inactive | |
| 1 | FLAG_ACTIVE | Flag active | ||||||
| 1 | 4 | BSH_Event_PowerOn | Switch on intelligent battery sensor in the last 2 seconds. | 01_BSH_Event_PowerOn | 0 | FlagInactive | Flag inactive | |
| 1 | FlagActive | Flag active | ||||||
| 1 | 5 | BSH_Event_EngineStart | Engine start detected. | 01_BSH_Event_EngineStart | 0 | FlagInactive | Flag inactive | |
| 1 | FlagActive | Flag active | ||||||
| 1 | 6 | BSH_Sulfation | Battery sulfation flag | 01_BSH_Sulfation | 0 | FlagInactive | Flag inactive | |
| 1 | FlagActive | Flag active | ||||||
| 1 | 7 | BSH_BatteryDefect | Battery fault flag | 01_BSH_BatteryDefect | 0 | FlagInactive | Flag inactive | |
| 1 | FlagActive | Flag active | ||||||
| 2 | 0 | BSH_SOCUpperTolerance | Upper tolerance of state of charge | 08_BSH_SOCUpperTolerance | 0...254 | 0...254 % | 1 % | |
| 3 | 0 | BSH_SOCLowerTolerance | Lower tolerance of state of charge | 08_BSH_SOCLowerTolerance | 0...254 | 0...254 % | 1 % | |
| 4 | 0 | BSH_CapacityLossTop | Loss of upper capacity (reversible) | 08_BSH_CapacityLossTop | 0...200 | 0...100 % | 0.5 % | |
| 5 | 0 | BSH_CapacityLossBottom | Lower capacity loss | 08_BSH_CapacityLossBottom | 0...200 | 0...100 % | 0.5 % | |
| 022h | 1 | 0 | BSH_BatteryCurrent | Battery current (charge = positive) | 24_BSH_BatteryCurrent | 0...4, 000, 000 | -2, 000, 000...2, 000, 000 | mA 1 mA |
| 4 | 0 | BSH_BatteryVoltage | Battery voltage | 16_BSH_Batteryvoltage | 0...50, 000 | 0...50 mV | 0.001 mV | |
| 6 | 0 | BSH_BatteryTemperature | Battery temperature | 09_BSH_BatteryTemp | 0...330 | -40...125°C | 0.5°C | |
| 7 | 1 | BSH_CurrentAutorange | Current measuring range (gain setting) | 02_BSH_CurrentAutorange | 0 | Range_Not_Defined | Not defined | |
| 1 | Current_range_l1 | Current range l1 (±1 A) | ||||||
| 2 | Current_range_l2 | Current range l2 (±1500 A) | ||||||
| 3 | Current_range_l3 | Current range l3 (not used) | ||||||
| 7 | 3 | - | - | - | - | - | - | |
| 7 | 7 | BSH_IBS_Error | Global intelligent battery sensor error flag | 01_BSH_IBS_Error | 1 | FlagActive | Flag active | |
| 025h | 1 | 0 | BSH_StateOfCharge | State of charge | 08_BSH_StateOfCharge | 0...200 | 0...100 % | 0.5 % |
| 2 | 0 | BSH_StateOfHealth | Condition and age of battery | 08_BSH_StateOfHealth | 0...200 | 0...100 % | 0.5 % | |
| 3 | 0 | BSH_EstVoltaDrop | Permissible voltage drop | 08_BSH_EstVoltaDrop | 0...254 | 0...12.7 V | 0.05 V | |
| 4 | 0 | BSH_OptChargeVolt | Recommended charging voltage | 08_BSH_OptChargeVolt | 0...254 | 5...17.7 V | 0.05 V | |
| 5 | 0 | BSH_AvgRi | Average inner resistance | 16_BSH_AvgRi | 0...2000 | 0...200 mΩ | 0.01 mΩ | |
| 026h | 1 | 0 | BSH_AvailableCapacity | Available capacity if the rechargeable battery is fully charged. | 16_BSH_AvailableCapacity | 0...5000 | 0...500 Ah | 0.1 Ah |
| 3 | 0 | BSH_DischargableAh | Discharge capacity | 16_BSH_AvailableCapacity | 0...5000 | 0...500 Ah | 0.1 Ah | |
| 5 | 0 | BSH_NominalCapacity | Adapted rated output | 08_BSH_NominalCapacity | 0...250 | 0...500 Ah | 2 Ah | |
| 6 | 0 | BSH_Recalibrated | SOC validity flag | 01_BSH_Recalibrated | 0 | Not_Recalibrated | Not recalibrated | |
| 1 | Recalibrated | Recalibrated | ||||||
| 6 | 1 | - | - | - | - | - | - | |
| 019h | 1 | 0 | LRD_ChargCurrent | Charging current | 08_LRD_ChargCurrent | 0...254 | 0...50.8 A | 0.2 A |
| 2 | 0 | - | - | - | - | - | - | |
| 2 | 2 | RsErr_LRD_CC | Error has occurred | 01_LRD_Error | 0 | NO_ERROR | No errors have occurred | |
| 1 | ERROR | Error has occurred | ||||||
| 2 | 3 | LRD_ChargActive | Charging is active. | 01_LRD_ChargActive | 0 | NOT_CHARGING | No charging process | |
| 1 | CHARGING_ACTIVE | Charging is active. | ||||||
| 2 | 4 | LRD_Status | Status value | 04_LRD_Status | 0 | NOT_CHARG_NO_ERR | No charging process and no error | |
| 1 | STEP1_SHORTCIRCUIT | Stage 1, short circuit | ||||||
| 2 | STEP2_WRG_POLARITY | Stage 2, wrong polarity | ||||||
| 3 | STEP3 | Stage 3 | ||||||
| 4 | STEP4_OUTPUT_FUSE_BLWN | Stage 4, output fuse blown. | ||||||
| 5 | STEP5_BAT_OVERHEAT | Stage 5, battery overheating | ||||||
| 6 | STEP6_BAT_UNDERHEAT | Stage 6, battery undercooling | ||||||
| 7 | STEP7_CHARGE_OVERHEAT | Stage 7, overheating during charging process | ||||||
| 8 | BAT_OVER_VOLT | Battery overvoltage | ||||||
| 9 | BAT_UNDER_VOLT | Battery undervoltage | ||||||
| 10 | BAT_TIMEOUT | Battery timeout | ||||||
| 03Dh | 1 | 0 | SlaveRespB0 | - | - | 6 5 |
- | Address "LRD" (6h) Address "BSH" (5h) |
| 2 | 0 | SlaveRespB1 | ||||||
| 3 | 0 | SlaveRespB2 | ||||||
| 4 | 0 | SlaveRespB3 | ||||||
| 5 | 0 | SlaveRespB4 | ||||||
| 6 | 0 | SlaveRespB5 | ||||||
| 7 | 0 | SlaveRespB6 | ||||||
| 8 | 0 | SlaveRespB7 | ||||||