PSM Logic Functions, Timer Block Function - GF54.21-D-3212TSB

Model 447, 448 

with code ED5 (Parameterisable special module) 

with code XM7 (MOPF II) 

Model 907, 910 

with code ED5 (Parameterisable special module) 

with code XJ4 (Modification year G4-I) 

G16501239Courtesy of MERCEDES-BENZ USA

Timer block function 

The timer block has a trigger input (E1 ), a reset input (E2 ) as well as an output (AA ) and an output (AB ), whereby output (AB ) is always the inversion of output (AA ). Outputs (AA , AB ) become active for a definable time after triggering.

A codable filter is connected upstream of the trigger input (E1 ) and upstream of the reset input (E2 ).

The reset input (E2 ) is always state-controlled and can reset the timer at any time.

It is possible to set whether the timer block is "retriggerable" and whether evaluation of the input signal is edge-controlled or state-controlled.

Coding of timer block 

The trigger input (E1 ) and the reset input (E2 ) of the timer block are coded by assigning an identification number (ID) of a signal from the signal pool. Dependencies on vehicle status can also be set.

The time parameter (PZt ) is an 8-bit value whose time (t) can also be set.

CODING VIA DATA ENTRY TABLE

Designation in data entry table Data entry bit width Data bit evaluation Meaning
B1_G1_TB1_Zeit [B1_G1_TB1_Time] 8 bit - 0 to 255
B1_G1_TB1_Zeitbasis [B1_G1_TB1_TimeBasis] 4 bit - 100 ms → 1
1 s → 2
10 s → 3
1 min → 4
10 min → 5
B1_G1_TB1_Art_der_Auswertung [...Type_ of_Evaluation] 1 bit - State-triggered → 0
Edge-triggered → 1
B1_G1_TB1_Flankenauswertung [B1_G1_TB1_EdgeEvaluation] 1 bit - Positive edge evaluation → 0
Negative edge evaluation → 1
B1_G1_TB1_Retriggerbarer_Timerblock [...Retriggerable_TimerBlock]
1 bit - Not "retriggerable" → 0
"Retriggerable" → 1
B1_G1_TB1_1 32 bit 1 bit Filter + input signal data entry signal ID for trigger input (E1 )
B1_G1_TB1_2 32 bit 1 bit Filter + input signal data entry signal ID for reset input (E2 )
SIGNAL ID OF OUTPUTS (AA, AB)

Designation in signal ID list Data bit width Meaning
SPS_G1_TB1 1 bit Signal ID of output (AA )
SPS_G1_TB1_inv 1 bit Signal ID of inverted output (AB )

The output signal of the timer block is written to the signal pool. At the same time, the inversion of the output signal is calculated and also placed in the signal pool.

The same applies for the other timer blocks with the naming conventions:

  Overview of system components for parameterizable special module (PSM)   GF54.21-D-9998TSB