Caravan Control Unit Parameters Of Analog Outputs, Function - GF54.21-D-5026TSA
Model 447
with code JA3 (Intelligent body control.)
with code XM7 (MOPF II)
Model 907, 910
with code JA3 (Intelligent body control.)
General
Analog outputs are used to set voltage values to, for example, control a device that executes corresponding actions depending on the voltage applied to its input.
The MB Advanced Control, control unit (N175) can operate 5 analog outputs.
Parameters, analog outputs
The analog outputs can switch a maximum of 10 V and a minimum of 250 mV.
The analog outputs have a resolution of 100 mV and a tolerance of 200 mV.
The analog outputs can supply a maximum of 2 mA.
The load on the analog outputs must be greater than 5 kOhm.
As soon as the read voltage value does not match the output voltage, the
MBAC switches off the analog output and creates an internal fault entry.