LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Metris Van Cargo >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instruments (04 Of 11) -- 447 Chassis >> Basic Knowledge >> PSM Logic Functions, Constants Function - GF54.21-S-3215TRA

PSM Logic Functions, Constants Function - GF54.21-S-3215TRA

Model 447 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

Model 448 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

Constants function 

A constant has a 16-bit output and no input. Its content is adjusted and coded using the data entry table.

IMPORTANT Signal identification number = Signal ID.

With the signal ID, the constant can be used like a signal from the signal pool.

CODING VIA DATA ENTRY TABLE

Designation in data entry table Data entry bit width Meaning
B1_G1_K1_value 16 bit Signal ID of the source of the constant value
B1_G1_K2_value 16 bit Signal ID of the source of the constant value
B1_G1_K3_value 16 bit Signal ID of the source of the constant value
B1_G1_K4_value 16 bit Signal ID of the source of the constant value
B1_G1_K5_value 16 bit Signal ID of the source of the constant value
SIGNAL ID OF OUTPUTS

Designation in signal ID list Data bit width Meaning
Out_G1_K1_value 16 bit Signal ID for constant 1 Konstante 1
Out_G1_K2_value 16 bit Signal ID for constant 2 Konstante 2
Out_G1_K3_value 16 bit Signal ID for constant 3 Konstante 3
Out_G1_K4_value 16 bit Signal ID for constant 4 Konstante 4
Out_G1_K5_value 16 bit Signal ID for constant 5 Konstante 5

The same applies for the other constants under observation of the naming convention:

  Parameterizable special module (PSM) control unit component description   GF54.21-S-5005TRA 
  Overview of system components for parameterizable special module (PSM)   GF54.21-S-9998TRA