PSM Arithmetic, Comparison Block Function - GF54.21-S-3158TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Parameterizable special module (PSM) arithmetic, comparison block, function
Result (E) = Input (c), if the configured comparison with input (a) and input (b) is "true". Otherwise, result (E) = result (d).
Signal identification number = Signal ID.
CODING
| Designation in data entry table | Data entry bit width | Meaning |
|---|---|---|
| AU_Compare_1_1 | "Unsigned" 16 bit | Signal ID of signal for input (a) |
| AU_Compare_1_2 | "Unsigned" 16 bit | Signal ID for input (b) |
| AU_Compare_1_3 | "Unsigned" 16 bit | Signal ID for input (c) |
| AU_Compare_1_4 | "Unsigned" 16 bit | Signal ID for input (d) |
| AU_Comp_1_Cfg | "Unsigned" 8 bit | Configuration of operator type: "0" → a > b "1" → a ≥ b "2" → a = b |
OUTPUT
| Designation in signal ID list | Data bit width | Meaning |
|---|---|---|
| Out_AU_Compare_1 | "Signed" 32 bit | Result (E) of comparison |
The same applies for other comparison blocks with the naming convention:
- "AU_Compare_<Block_number>_<Parameter_designation>"
- "Out_AU_Compare_<-Block_number>"
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |