PLC Group 9 Signal List, PSM Function - GF54.21-S-3129TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 9, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G9_HB | 0x1195 | PLC group 9, hysteresis block: Output not inverted | Bit | 0 | PLC | 553 |
| Out_G9_HB_inv | 0x1196 | PLC group 9, hysteresis block: Output inverted | Bit | 1 | PLC | 554 |
| Out_G9_SS1_A | 0x1197 | PLC group 9, threshold switch 1: Output A | Bit | 0 | PLC | 555 |
| Out_G9_SS1_B | 0x1198 | PLC group 9, threshold switch 1: Output B | Bit | 0 | PLC | 556 |
| Out_G9_SS1_C | 0x1199 | PLC group 9, threshold switch 1: Output C | Bit | 0 | PLC | 557 |
| Out_G9_SS1_D | 0x119A | PLC group 9, threshold switch 1: Output D | Bit | 0 | PLC | 558 |
| Out_G9_SS2_A | 0x119B | PLC group 9, threshold switch 2: Output A | Bit | 0 | PLC | 559 |
| Out_G9_SS2_B | 0x119C | PLC group 9, threshold switch 2: Output B | Bit | 0 | PLC | 560 |
| Out_G9_SS2_C | 0x119D | PLC group 9, threshold switch 2: Output C | Bit | 0 | PLC | 561 |
| Out_G9_SS2_D | 0x119E | PLC group 9, threshold switch 2: Output D | Bit | 0 | PLC | 562 |
| Out_G9_LB1 | 0x119F | PLC group 9, logic block 1: Output not inverted | Bit | 0 | PLC | 563 |
| Out_G9_LB1_inv | 0x11A0 | PLC group 9, logic block 1: Output inverted | Bit | 1 | PLC | 564 |
| Out_G9_LB2 | 0x11A1 | PLC group 9, logic block 2: Output not inverted | Bit | 0 | PLC | 565 |
| Out_G9_LB2_inv | 0x11A2 | PLC group 9, logic block 2: Output inverted | Bit | 1 | PLC | 566 |
| Out_G9_LB3 | 0x11A3 | PLC group 9, logic block 3: Output not inverted | Bit | 0 | PLC | 567 |
| Out_G9_LB3_inv | 0x11A4 | PLC group 9, logic block 3: Output inverted | Bit | 1 | PLC | 568 |
| Out_G9_LB4 | 0x11A5 | PLC group 9, logic block 4: Output not inverted | Bit | 0 | PLC | 569 |
| Out_G9_LB4_inv | 0x11A6 | PLC group 9, logic block 4: Output inverted | Bit | 1 | PLC | 570 |
| Out_G9_LB5 | 0x11A7 | PLC group 9, logic block 5: Output not inverted | Bit | 0 | PLC | 571 |
| Out_G9_LB5_inv | 0x11A8 | PLC group 9, logic block 5: Output inverted | Bit | 1 | PLC | 572 |
| Out_G9_LB6 | 0x11A9 | PLC group 9, logic block 6: Output not inverted | Bit | 0 | PLC | 573 |
| Out_G9_LB6_inv | 0x11AA | PLC group 9, logic block 6: Output inverted | Bit | 1 | PLC | 574 |
| Out_G9_LB7 | 0x11AB | PLC group 9, logic block 7: Output not inverted | Bit | 0 | PLC | 575 |
| Out_G9_LB7_inv | 0x11AC | PLC group 9, logic block 7: Output inverted | Bit | 1 | PLC | 576 |
| Out_G9_LB8 | 0x11AD | PLC group 9, logic block 8: Output not inverted | Bit | 0 | PLC | 577 |
| Out_G9_LB8_inv | 0x11AE | PLC group 9, logic block 8: Output inverted | Bit | 1 | PLC | 578 |
| Out_G9_FF1 | 0x306D | PLC group 9, flip-flop 1: Output not inverted | Data word (Word) | 0 | PLC | 579 |
| Out_G9_FF1_inv | 0x11AF | PLC group 9, flip-flop 1: Output inverted | Bit | 1 | PLC | 580 |
| Out_G9_FF2 | 0x306E | PLC group 9, flip-flop 2: Output not inverted | Data word (Word) | 0 | PLC | 581 |
| Out_G9_FF2_inv | 0x11B0 | PLC group 9, flip flop 2: Output inverted | Bit | 1 | PLC | 582 |
| Out_G9_TB | 0x11B1 | PLC group 9, timer block: Output not inverted | Bit | 0 | PLC | 583 |
| Out_G9_TB_inv | 0x11B2 | PLC group 9, timer block: Output inverted | Bit | 1 | PLC | 584 |
| Out_G9_CNT | 0x306F | PLC group 9, counter | Data word (Word) | 0 | PLC | 585 |
| Out_G9_WT1 | 0x3070 | PLC group 9, value table 1 | Data word (Word) | 0 | PLC | 586 |
| Out_G9_K1_Value | 0x3071 | PLC group 9, constant 1 | Data word (Word) | 0 | PLC | 587 |
| Out_G9_K2_Value | 0x3072 | PLC group 9, constant 2 | Bit | 0 | PLC | 588 |
| Out_G9_K3_Value | 0x3073 | PLC group 9, constant 3 | Data word (Word) | 0 | PLC | 589 |
| Out_G9_K4_Value | 0x3074 | PLC group 9, constant 4 | Data word (Word) | 0 | PLC | 590 |
| Out_G9_K5_Value | 0x3075 | PLC group 9, constant 5 | Data word (Word) | 0 | PLC | 591 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |