PLC Group 7 Signal List, PSM Function - GF54.21-S-3127TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST OF PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 7 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G7_HB | 0x1159 | PLC Group 7, hysteresis block: Output not inverted | Bit | 0 | PLC | 475 |
| Out_G7_HB_inv | 0x115A | PLC Group 7, hysteresis block: Output inverted | Bit | 1 | PLC | 476 |
| Out_G7_SS1_A | 0x115B | PLC Group 7, threshold switch 1: Output A | Bit | 0 | PLC | 477 |
| Out_G7_SS1_B | 0x115C | PLC Group 7, threshold switch 1: Output B | Bit | 0 | PLC | 478 |
| Out_G7_SS1_C | 0x115D | PLC Group 7, threshold switch 1: Output C | Bit | 0 | PLC | 479 |
| Out_G7_SS1_D | 0x115E | PLC Group 7, threshold switch 1: Output D | Bit | 0 | PLC | 480 |
| Out_G7_SS2_A | 0x115F | PLC Group 7, threshold switch 2: Output A | Bit | 0 | PLC | 481 |
| Out_G7_SS2_B | 0x1160 | PLC Group 7, threshold switch 2: Output B | Bit | 0 | PLC | 482 |
| Out_G7_SS2_C | 0x1161 | PLC Group 7, threshold switch 2: Output C | Bit | 0 | PLC | 483 |
| Out_G7_SS2_D | 0x1162 | PLC Group 7, threshold switch 2: Output D | Bit | 0 | PLC | 484 |
| Out_G7_LB1 | 0x1163 | PLC Group 7, logic block 1: Output not inverted | Bit | 0 | PLC | 485 |
| Out_G7_LB1_inv | 0x1164 | PLC Group 7, logic block 1: Output inverted | Bit | 1 | PLC | 486 |
| Out_G7_LB2 | 0x1165 | PLC Group 7, logic block 2: Output not inverted | Bit | 0 | PLC | 487 |
| Out_G7_LB2_inv | 0x1166 | PLC Group 7, logic block 2: Output inverted | Bit | 1 | PLC | 488 |
| Out_G7_LB3 | 0x1167 | PLC Group 7, logic block 3: Output not inverted | Bit | 0 | PLC | 489 |
| Out_G7_LB3_inv | 0x1168 | PLC Group 7, logic block 3: Output inverted | Bit | 1 | PLC | 490 |
| Out_G7_LB4 | 0x1169 | PLC Group 7, logic block 4: Output not inverted | Bit | 0 | PLC | 491 |
| Out_G7_LB4_inv | 0x116A | PLC Group 7, logic block 4: Output inverted | Bit | 1 | PLC | 492 |
| Out_G7_LB5 | 0x116B | PLC Group 7, logic block 5: Output not inverted | Bit | 0 | PLC | 493 |
| Out_G7_LB5_inv | 0x116C | PLC Group 7, logic block 5: Output inverted | Bit | 1 | PLC | 494 |
| Out_G7_LB6 | 0x116D | PLC Group 7, logic block 6: Output not inverted | Bit | 0 | PLC | 495 |
| Out_G7_LB6_inv | 0x116E | PLC Group 7, logic block 6: Output inverted | Bit | 1 | PLC | 496 |
| Out_G7_LB7 | 0x116F | PLC Group 7, logic block 7: Output not inverted | Bit | 0 | PLC | 497 |
| Out_G7_LB7_inv | 0x1170 | PLC Group 7, logic block 7: Output inverted | Bit | 1 | PLC | 498 |
| Out_G7_LB8 | 0x1171 | PLC Group 7, logic block 8: Output not inverted | Bit | 0 | PLC | 499 |
| G7_LB8_inv | 0x1172 | PLC Group 7, logic block 8: Output inverted | Bit | 1 | PLC | 500 |
| Out_G7_FF1 | 0x305B | PLC Group 7, flip-flop 1: Output not inverted | Data word (Word) | 0 | PLC | 501 |
| Out_G7_FF1_inv | 0x1173 | PLC Group 7, flip flop 1: Output inverted | Bit | 1 | PLC | 502 |
| Out_G7_FF2 | 0x305C | PLC Group 7, flip-flop 2: Output not inverted | Data word (Word) | 0 | PLC | 503 |
| Out_G7_FF2_inv | 0x1174 | PLC Group 7, flip flop 2: Output inverted | Bit | 1 | PLC | 504 |
| Out_G7_TB | 0x1175 | PLC Group 7, timer block: Output not inverted | Bit | 0 | PLC | 505 |
| Out_G7_TB_inv | 0x1176 | PLC Group 7, timer block: Output inverted | Bit | 1 | PLC | 506 |
| Out_G7_CNT | 0x305D | PLC Group 7, counter | Data word (Word) | 0 | PLC | 507 |
| Out_G7_WT1 | 0x305E | PLC Group 7, value table 1 | Data word (Word) | 0 | PLC | 508 |
| Out_G7_K1_Value | 0x305F | PLC Group 7, constants 1 | Data word (Word) | 0 | PLC | 509 |
| Out_G7_K2_Value | 0x3060 | PLC Group 7, constants 2 | Data word (Word) | 0 | PLC | 510 |
| Out_G7_K3_Value | 0x3061 | PLC Group 7, constants 3 | Bit | 0 | PLC | 511 |
| Out_G7_K4_Value | 0x3062 | PLC Group 7, constants 4 | Data word (Word) | 0 | PLC | 512 |
| Out_G7_K5_Value | 0x3063 | PLC Group 7, constants 5 | Data word (Word) | 0 | PLC | 513 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||