PLC Group 3 Signal List, PSM Function - GF54.21-S-3123TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 3, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G3_HB | 0x10E1 | PLC group 3 hysteresis block: Output not inverted | Bit | 0 | PLC | 319 |
| Out_G3_HB_inv | 0x10E2 | PLC group 3 hysteresis block: Output inverted | Bit | 1 | PLC | 320 |
| Out_G3_SS1_A | 0x10E3 | PLC group 3, threshold switch 1: Output A | Bit | 0 | PLC | 321 |
| Out_G3_SS1_B | 0x10E4 | PLC group 3, threshold switch 1: Output B | Bit | 0 | PLC | 322 |
| Out_G3_SS1_C | 0x10E5 | PLC group 3, threshold switch 1: Output C | Bit | 0 | PLC | 323 |
| Out_G3_SS1_D | 0x10E6 | PLC group 3, threshold switch 1: Output D | Bit | 0 | PLC | 324 |
| Out_G3_SS2_A | 0x10E7 | PLC group 3, threshold switch 2: Output A | Bit | 0 | PLC | 325 |
| Out_G3_SS2_B | 0x10E8 | PLC group 3, threshold switch 2: Output B | Bit | 0 | PLC | 326 |
| Out_G3_SS2_C | 0x10E9 | PLC group 3, threshold switch 2: Output C | Bit | 0 | PLC | 327 |
| Out_G3_SS2_D | 0x10EA | PLC group 3, threshold switch 2: Output D | Bit | 0 | PLC | 328 |
| Out_G3_LB1 | 0x10EB | PLC group 3, logic block 1: Output not inverted | Bit | 0 | PLC | 329 |
| Out_G3_LB1_inv | 0x10EC | PLC group 3, logic block 1: Output inverted | Bit | 1 | PLC | 330 |
| Out_G3_LB2 | 0x10ED | PLC group 3, logic block 2: Output not inverted | Bit | 0 | PLC | 331 |
| Out_G3_LB2_inv | 0x10EE | PLC group 3, logic block 2: Output inverted | Bit | 1 | PLC | 332 |
| Out_G3_LB3 | 0x10EF | PLC group 3, logic block 3: Output not inverted | Bit | 0 | PLC | 333 |
| Out_G3_LB3_inv | 0x10F0 | PLC group 3, logic block 3: Output inverted | Bit | 1 | PLC | 334 |
| Out_G3_LB4 | 0x10F1 | PLC group 3, logic block 4: Output not inverted | Bit | 0 | PLC | 335 |
| Out_G3_LB4_inv | 0x10F2 | PLC group 3, logic block 4: Output inverted | Bit | 1 | PLC | 336 |
| Out_G3_LB5 | 0x10F3 | PLC group 3, logic block 5: Output not inverted | Bit | 0 | PLC | 337 |
| Out_G3_LB5_inv | 0x10F4 | PLC group 3, logic block 5: Output inverted | Bit | 1 | PLC | 338 |
| Out_G3_LB6 | 0x10F5 | PLC group 3, logic block 6: Output not inverted | Bit | 0 | PLC | 339 |
| Out_G3_LB6_inv | 0x10F6 | PLC group 3, logic block 6: Output inverted | Bit | 1 | PLC | 340 |
| Out_G3_LB7 | 0x10F7 | PLC group 3, logic block 7: Output not inverted | Bit | 0 | PLC | 341 |
| Out_G3_LB7_inv | 0x10F8 | PLC group 3, logic block 7: Output inverted | Bit | 1 | PLC | 342 |
| Out_G3_LB8 | 0x10F9 | PLC group 3, logic block 8: Output not inverted | Bit | 0 | PLC | 343 |
| Out_G3_LB8_inv | 0x10FA | PLC group 3, logic block 8: Output inverted | Bit | 1 | PLC | 344 |
| Out_G3_FF1 | 0x3037 | PLC group 3, flip-flop 1: Output not inverted | Data word (Word) | 0 | PLC | 345 |
| Out_G3_FF1_inv | 0x10FB | PLC group 3, flip flop 1: Output inverted | Bit | 1 | PLC | 346 |
| Out_G3_FF2 | 0x3038 | PLC group 3, flip-flop 2: Output not inverted | Data word (Word) | 0 | PLC | 347 |
| Out_G3_FF2_inv | 0x10FC | PLC group 3, flip flop 2: Output inverted | Bit | 1 | PLC | 348 |
| Out_G3_TB | 0x10FD | PLC group 3, timer block: Output not inverted | Bit | 0 | PLC | 349 |
| Out_G3_TB_inv | 0x10FE | PLC group 3, timer block: Output inverted | Bit | 1 | PLC | 350 |
| Out_G3_CNT | 0x3039 | PLC group 3, counter | Data word (Word) | 0 | PLC | 351 |
| Out_G3_WT1 | 0x303A | PLC group 3, value table 1 | Data word (Word) | 0 | PLC | 352 |
| Out_G3_K1_Value | 0x303B | PLC group 3, constant 1 | Data word (Word) | 0 | PLC | 353 |
| Out_G3_K2_Value | 0x303C | PLC group 3, constant 2 | Data word (Word) | 0 | PLC | 354 |
| Out_G3_K3_Value | 0x303D | PLC group 3, constant 3 | Data word (Word) | 0 | PLC | 355 |
| Out_G3_K4_Value | 0x303E | PLC group 3, constant 4 | Data word (Word) | 0 | PLC | 356 |
| Out_G3_K5_Value | 0x303F | PLC group 3, constant 5 | Data word (Word) | 0 | PLC | 357 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |