PLC Group 2 Signal List, PSM Function - GF54.21-S-3122TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 2 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G2_HB | 0x10C3 | PLC group 2, hysteresis block: Output not inverted | Bit | 0 | PLC | 280 |
| Out_G2_HB_inv | 0x10C4 | PLC group 2, hysteresis block: Output inverted | Bit | 1 | PLC | 281 |
| Out_G2_SS1_A | 0x10C5 | PLC group 2, threshold switch 1: Output A | Bit | 0 | PLC | 282 |
| Out_G2_SS1_B | 0x10C6 | PLC group 2, threshold switch 1: Output B | Bit | 0 | PLC | 283 |
| Out_G2_SS1_C | 0x10C7 | PLC group 2, threshold switch 1: Output C | Bit | 0 | PLC | 284 |
| Out_G2_SS1_D | 0x10C8 | PLC group 2, threshold switch 1: Output D | Bit | 0 | PLC | 285 |
| Out_G2_SS2_A | 0x10C9 | PLC group 2, threshold switch 2: Output A | Bit | 0 | PLC | 286 |
| Out_G2_SS2_B | 0x10CA | PLC group 2, threshold switch 2: Output B | Bit | 0 | PLC | 287 |
| Out_G2_SS2_C | 0x10CB | PLC group 2, threshold switch 2: Output C | Bit | 0 | PLC | 288 |
| Out_G2_SS2_D | 0x10CC | PLC group 2, threshold switch 2: Output D | Bit | 0 | PLC | 289 |
| Out_G2_LB1 | 0x10CD | PLC group 2, logic block 1: Output not inverted | Bit | 0 | PLC | 290 |
| Out_G2_LB1_inv | 0x10CE | PLC group 2, logic block 1: Output inverted | Bit | 1 | PLC | 291 |
| Out_G2_LB2 | 0x10CF | PLC group 2, logic block 2: Output not inverted | Bit | 0 | PLC | 292 |
| Out_G2_LB2_inv | 0x10D0 | PLC group 2, logic block 2: Output inverted | Bit | 1 | PLC | 293 |
| Out_G2_LB3 | 0x10D1 | PLC group 2, logic block 3: Output not inverted | Bit | 0 | PLC | 294 |
| Out_G2_LB3_inv | 0x10D2 | PLC group 2, logic block 3: Output inverted | Bit | 1 | PLC | 295 |
| Out_G2_LB4 | 0x10D3 | PLC group 2, logic block 4: Output not inverted | Bit | 0 | PLC | 296 |
| Out_G2_LB4_inv | 0x10D4 | PLC group 2, logic block 4: Output inverted | Bit | 1 | PLC | 297 |
| Out_G2_LB5 | 0x10D5 | PLC group 2, logic block 5: Output not inverted | Bit | 0 | PLC | 298 |
| Out_G2_LB5_inv | 0x10D6 | PLC group 2, logic block 5: Output inverted | Bit | 1 | PLC | 299 |
| Out_G2_LB6 | 0x10D7 | PLC group 2, logic block 6: Output not inverted | Bit | 0 | PLC | 300 |
| Out_G2_LB6_inv | 0x10D8 | PLC group 2, logic block 6: Output inverted | Bit | 1 | PLC | 301 |
| Out_G2_LB7 | 0x10D9 | PLC group 2, logic block 7: Output not inverted | Bit | 0 | PLC | 302 |
| Out_G2_LB7_inv | 0x10DA | PLC group 2, logic block 7: Output inverted | Bit | 1 | PLC | 303 |
| Out_G2_LB8 | 0x10DB | PLC group 2, logic block 8: Output not inverted | Bit | 0 | PLC | 304 |
| Out_G2_LB8_inv | 0x10DC | PLC group 2, logic block 8: Output inverted | Bit | 1 | PLC | 305 |
| Out_G2_FF1 | 0x302E | PLC group 2, flip-flop 1: Output not inverted | Data item (Word) | 0 | PLC | 306 |
| Out_G2_FF1_inv | 0x10DD | PLC group 2, flip-flop 1: Output inverted | Bit | 1 | PLC | 307 |
| Out_G2_FF2 | 0x302F | PLC group 2, flip-flop 2: Output not inverted | Data item (Word) | 0 | PLC | 308 |
| Out_G2_FF2_inv | 0x10DE | PLC group 2, flip-flop 2: Output inverted | Bit | 1 | PLC | 309 |
| Out_G2_TB | 0x10DF | PLC group 2, timer block: Output not inverted | Bit | 0 | PLC | 310 |
| Out_G2_TB_inv | 0x10E0 | PLC group 2, timer block: Output inverted | Bit | 1 | PLC | 311 |
| Out_G2_CNT | 0x3030 | PLC group 2, counter | Data item (Word) | 0 | PLC | 312 |
| Out_G2_WT1 | 0x3031 | PLC group 2, value table 1 | Data item (Word) | 0 | PLC | 313 |
| Out_G2_K1_value | 0x3032 | PLC group 2, constant 1 | Data item (Word) | 0 | PLC | 314 |
| Out_G2_K2_value | 0x3033 | PLC group 2, constant 2 | Data item (Word) | 0 | PLC | 315 |
| Out_G2_K3_value | 0x3034 | PLC group 2, constant 3 | Data item (Word) | 0 | PLC | 316 |
| Out_G2_K4_value | 0x3035 | PLC group 2, constant 4 | Data item (Word) | 0 | PLC | 317 |
| Out_G2_K5_value | 0x3036 | PLC group 2, constant 5 | Data item (Word) | 0 | PLC | 318 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |