PLC Group 11 Signal List, PSM Function - GF54.21-S-3120A
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROL (PLC) GROUP 11, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G11_HB | 0x11D1 | PLC Group 11, hysteresis block: Output not inverted | Bit | 0 | PLC | 631 |
| Out_G11_HB_inv | 0x11D2 | PLC Group 11, hysteresis block: Output inverted | Bit | 1 | PLC | 632 |
| Out_G11_SS1_A | 0x11D3 | PLC Group 11, threshold switch 1: Output A | Bit | 0 | PLC | 633 |
| Out_G11_SS1_B | 0x11D4 | PLC Group 11, threshold switch 1: Output B | Bit | 0 | PLC | 634 |
| Out_G11_SS1_C | 0x11D5 | PLC Group 11, threshold switch 1: Output C | Bit | 0 | PLC | 635 |
| Out_G11_SS1_D | 0x11D6 | PLC Group 11, threshold switch 1: Output D | Bit | 0 | PLC | 636 |
| Out_G11_SS2_A | 0x11D7 | PLC Group 11, threshold switch 2: Output A | Bit | 0 | PLC | 637 |
| Out_G11_SS2_B | 0x11D8 | PLC Group 11, threshold switch 2: Output B | Bit | 0 | PLC | 638 |
| Out_G11_SS2_C | 0x11D9 | PLC Group 11, threshold switch 2: Output C | Bit | 0 | PLC | 639 |
| Out_G11_SS2_D | 0x11DA | PLC Group 11, threshold switch 2: Output D | Bit | 0 | PLC | 640 |
| Out_G11_LB1 | 0x11DB | PLC Group 11, logic block 1: Output not inverted | Bit | 0 | PLC | 641 |
| Out_G11_LB1_inv | 0x11DC | PLC Group 11, logic block 1: Output inverted | Bit | 1 | PLC | 642 |
| Out_G11_LB2 | 0x11DD | PLC Group 11, logic block 2: Output not inverted | Bit | 0 | PLC | 643 |
| Out_G11_LB2_inv | 0x11DE | PLC Group 11, logic block 2: Output inverted | Bit | 1 | PLC | 644 |
| Out_G11_LB3 | 0x11DF | PLC Group 11, logic block 3: Output not inverted | Bit | 0 | PLC | 645 |
| Out_G11_LB3_inv | 0x11E0 | PLC Group 11, logic block 3: Output inverted | Bit | 1 | PLC | 646 |
| Out_G11_LB4 | 0x11E1 | PLC Group 11, logic block 4: Output not inverted | Bit | 0 | PLC | 647 |
| Out_G11_LB4_inv | 0x11E2 | PLC Group 11, logic block 4: Output inverted | Bit | 1 | PLC | 648 |
| Out_G11_LB5 | 0x11E3 | PLC Group 11, logic block 5: Output not inverted | Bit | 0 | PLC | 649 |
| Out_G11_LB5_inv | 0x11E4 | PLC Group 11, logic block 5: Output inverted | Bit | 1 | PLC | 650 |
| Out_G11_LB6 | 0x11E5 | PLC Group 11, logic block 6: Output not inverted | Bit | 0 | PLC | 651 |
| Out_G11_LB6_inv | 0x11E6 | PLC Group 11, logic block 6: Output inverted | Bit | 1 | PLC | 652 |
| Out_G11_LB7 | 0x11E7 | PLC Group 11, logic block 7: Output not inverted | Bit | 0 | PLC | 653 |
| Out_G11_LB7_inv | 0x11E8 | PLC Group 11, logic block 7: Output inverted | Bit | 1 | PLC | 654 |
| Out_G11_LB8 | 0x11E9 | PLC Group 11, logic block 8: Output not inverted | Bit | 0 | PLC | 655 |
| Out_G11_LB8_inv | 0x11EA | PLC Group 11, logic block 8: Output inverted | Bit | 1 | PLC | 656 |
| Out_G11_FF 1 | 0x307F | PLC Group 11, flip-flop 1: Output not inverted | Data word (Word) | 0 | PLC | 657 |
| Out_G11_FF 1_inv | 0x11EB | PLC Group 11, flip flop 1: Output inverted | Bit | 1 | PLC | 658 |
| Out_G11_FF2 | 0x3080 | PLC Group 11, flip-flop 2: Output not inverted | Data word (Word) | 0 | PLC | 659 |
| Out_G11_FF2_inv | 0x11EC | PLC Group 11, flip flop 2: Output inverted | Bit | 1 | PLC | 660 |
| Out_G11_TB | 0x11ED | PLC Group 11, timer block: Output not inverted | Bit | 0 | PLC | 661 |
| Out_G11_TB_inv | 0x11EE | PLC Group 11, timer block: Output inverted | Bit | 1 | PLC | 662 |
| Out_G11_CNT | 0x3081 | PLC Group 11, counter | Data word (Word) | 0 | PLC | 663 |
| Out_G11_WT1 | 0x3082 | PLC Group 11, value table 1 | Data word (Word) | 0 | PLC | 664 |
| Out_G11_K1_Value | 0x3083 | PLC Group 11, constants 1 | Data word (Word) | 0 | PLC | 665 |
| Out_G11_K2_Value | 0x3084 | PLC Group 11, constants 2 | Data word (Word) | 0 | PLC | 666 |
| Out_G11_K3_Value | 0x3085 | PLC Group 11, constants 3 | Data word (Word) | 0 | PLC | 667 |
| Out_G11_K4_Value | 0x3086 | PLC Group 11, constants 4 | Data word (Word) | 0 | PLC | 668 |
| Out_G11_K5_Value | 0x3087 | PLC Group 11, constants 5 | Data word (Word) | 0 | PLC | 669 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |