PLC Group 1 Signal List, PSM Function - GF54.21-S-3118TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 1 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_G1_HB | 0x10A5 | PLC group 1, hysteresis block: Output not inverted | Bit | 0 | PLC | 241 |
| Out_G1_HB_inv | 0x10A6 | PLC group 1, hysteresis block: Output inverted | Bit | 1 | PLC | 242 |
| Out_G1_SS1_A | 0x10A7 | PLC group 1, threshold switch 1: Output A | Bit | 0 | PLC | 243 |
| Out_G1_SS1_B | 0x10A8 | PLC group 1, threshold switch 1: Output B | Bit | 0 | PLC | 244 |
| Out_G1_SS1_C | 0x10A9 | PLC group 1, threshold switch 1: Output C | Bit | 0 | PLC | 245 |
| Out_G1_SS1_D | 0x10AA | PLC group 1, threshold switch 1: Output D | Bit | 0 | PLC | 246 |
| Out_G1_SS2_A | 0x10AB | PLC group 1, threshold switch 2: Output A | Bit | 0 | PLC | 247 |
| Out_G1_SS2_B | 0x10AC | PLC group 1, threshold switch 2: Output B | Bit | 0 | PLC | 248 |
| Out_G1_SS2_C | 0x10AD | PLC group 1, threshold switch 2: Output C | Bit | 0 | PLC | 249 |
| Out_G1_SS2_D | 0x10AE | PLC group 1, threshold switch 2: Output D | Bit | 0 | PLC | 250 |
| Out_G1_LB1 | 0x10AF | PLC group 1, logic block 1: Output not inverted | Bit | 0 | PLC | 251 |
| Out_G1_LB1_inv | 0x10B0 | PLC group 1, logic block 1: Output inverted | Bit | 1 | PLC | 252 |
| Out_G1_LB2 | 0x10B1 | PLC group 1, logic block 2: Output not inverted | Bit | 0 | PLC | 253 |
| Out_G1_LB2_inv | 0x10B2 | PLC group 1, logic block 2: Output inverted | Bit | 1 | PLC | 254 |
| Out_G1_LB3 | 0x10B3 | PLC group 1, logic block 3: Output not inverted | Bit | 0 | PLC | 255 |
| Out_G1_LB3_inv | 0x10B4 | PLC group 1, logic block 3: Output inverted | Bit | 1 | PLC | 256 |
| Out_G1_LB4 | 0x10B5 | PLC group 1, logic block 4: Output not inverted | Bit | 0 | PLC | 257 |
| Out_G1_LB4_inv | 0x10B6 | PLC group 1, logic block 4: Output inverted | Bit | 1 | PLC | 258 |
| Out_G1_LB5 | 0x10B7 | PLC group 1, logic block 5: Output not inverted | Bit | 0 | PLC | 259 |
| Out_G1_LB5_inv | 0x10B8 | PLC group 1, logic block 5: Output inverted | Bit | 1 | PLC | 260 |
| Out_G1_LB6 | 0x10B9 | PLC group 1, logic block 6: Output not inverted | Bit | 0 | PLC | 261 |
| Out_G1_LB6_inv | 0x10BA | PLC group 1, logic block 6: Output inverted | Bit | 1 | PLC | 262 |
| Out_G1_LB7 | 0x10BB | PLC group 1, logic block 7: Output not inverted | Bit | 0 | PLC | 263 |
| Out_G1_LB7_inv | 0x10BC | PLC group 1, logic block 7: Output inverted | Bit | 1 | PLC | 264 |
| Out_G1_LB8 | 0x10BD | PLC group 1, logic block 8: Output not inverted | Bit | 0 | PLC | 265 |
| Out_G1_LB8_inv | 0x10BE | PLC group 1, logic block 8: Output inverted | Bit | 1 | PLC | 266 |
| Out_G1_FF1 | 0x3025 | PLC group 1, flip flop 1: Output not inverted | Data item (Word) | 0 | PLC | 267 |
| Out_G1_FF1_inv | 0x10BF | PLC group 1, flip flop 1: Output inverted | Bit | 1 | PLC | 268 |
| Out_G1_FF2 | 0x3026 | PLC group 1, flip-flop 2: Output not inverted | Bit | 0 | PLC | 269 |
| Out_G1_FF2_inv | 0x10C0 | PLC group 1, flip-flop 2: Output inverted | Bit | 1 | PLC | 270 |
| Out_G1_TB | 0x10C1 | PLC group 1, timer block: Output not inverted | Bit | 0 | PLC | 271 |
| Out_G1_TB_inv | 0x10C2 | PLC group 1, timer block: Output inverted | Bit | 1 | PLC | 272 |
| Out_G1_CNT | 0x3027 | PLC group 1, counter | Data item (Word) | 0 | PLC | 273 |
| Out_G1_WT1 | 0x3028 | PLC group 1, value table 1 | Data item (Word) | 0 | PLC | 274 |
| Out_G1_K1_value | 0x3029 | PLC group 1, constant 1 | Data item (Word) | 0 | PLC | 275 |
| Out_G1_K2_value | 0x302A | PLC group 1, constant 2 | Data item (Word) | 0 | PLC | 276 |
| Out_G1_K3_value | 0x302B | PLC group 1, constant 3 | Data item (Word) | 0 | PLC | 277 |
| Out_G1_K4_value | 0x302C | PLC group 1, constant 4 | Data item (Word) | 0 | PLC | 278 |
| Out_G1_K5_value | 0x302D | PLC group 1, constant 5 | Data item (Word) | 0 | PLC | 279 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |