Internal Software Component Signal List, PSM Function - GF54.21-S-3116TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
INTERNAL SOFTWARE COMPONENT SIGNAL LIST, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| SWCi_CiA447_Taximeter_Occu pied | 0x1050 | Status of taximeter: "0" = Not used "1" = Used |
Bit | 0 | Application | 148 |
| SWCi_CiA447_Taximeter_Free | 0x1051 | Status of taximeter: "0" = Not free "1" = Free |
Bit | 0 | Application | 149 |
| SWCi_KL15R_to_KL15Xms | 0x1052 | Status of terminal 15 from OFF to ON, signal duration 60 ms | Bit | 0 | Application | 150 |
| SWCi_noExtLk | 0x1053 | Status of central locking system: "0" = "CLkS_Stat = EXT_LK" or "CLkS_Stat = SNA" "1" = All others |
Bit | 0 | Application | 151 |
| SWCi_O6007_s_accessory | 0x201E | CANopen Object 6007, status of ignition, terminal 15R: "0" = OFF "1" = ON "2" = Error "3" = Not available |
Byte | 3 | Application | 152 |
| SWCi_O6007_s_ignition_lock | 0x201F | CANopen Object 6007, status of ignition OFF: "0" = OFF "1" = ON "2" = Error "3" = Not available |
Byte | 3 | Application | 153 |
| SWCi_O6007_s_ignition_on | 0x2020 | CANopen Object 6007, status of ignition ON: "0" = OFF "1" = ON "2" = Error "3" = Not available |
Byte | 3 | Application | 154 |
| SWCi_O6007_s_ignition_start | 0x2021 | CANopen Object 6007, status of ignition engine start: "0" = OFF "1" = ON "2" = Error "3" = Not available |
Byte | 3 | Application | 155 |
| SWCi_O6025_c_recair | 0x1054 | CANopen Object 6025, recirculated air: "0" = OFF "1" = ON |
Bit | 0 | Application | 156 |
| SWCi_O604C_c_gclf | 0x1055 | CANopen Object 604C, turn signal light: "0" = OFF "1" = ON |
Bit | 0 | Application | 157 |
| SWCi_O6071_c_radio_power_off | 0x1056 | CANopen Object 6071, switch off power supply for radio: "0" = Do not switch off "1" = Switch off |
Bit | 0 | Application | 158 |
| SWCi_O608F_c_video | 0x1057 | CANopen Object 608F, Video: "0" = Enable "1" = Lock |
Bit | 0 | Application | 159 |
| SWCi_O6140_c_ffl | 0x1058 | CANopen Object 6140, emergency vehicle warning light command, left front turn signal indicator: "0" = OFF "1" = ON |
Bit | 0 | Application | 160 |
| SWCi_O6140_c_ffr | 0x1059 | CANopen Object 6140, emergency vehicle warning light command, right front turn signal indicator: "0" = OFF "1" = ON |
Bit | 0 | Application | 161 |
| SWCi_O6140_c_mfl | 0x105A | CANopen Object 6140, emergency vehicle warning light command, turn signal lamp in left outside mirror: "0" = OFF "1" = ON |
Bit | 0 | Application | 162 |
| SWCi_O6140_c_mfr | 0x105B | CANopen Object 6140, emergency vehicle warning light command, turn signal lamp in right outside mirror: "0" = OFF "1" = ON |
Bit | 0 | Application | 163 |
| SWCi_O6140_c_rfl | 0x105C | CANopen Object 6140, emergency vehicle warning light command, left rear left turn signal lamp: "0" = OFF "1" = ON |
Bit | 0 | Application | 164 |
| Signal-ID_SWCi_O6140_c_rfr | 0x105D | CANopen Object 6140, emergency vehicle warning light command, right rear left turn signal lamp: "0" = OFF "1" = ON |
Bit | 0 | Application | 165 |
| SWCi_O6140_c_sfl | 0x105E | CANopen Object 6140, emergency vehicle warning light command, left side turn signal: "0" = OFF "1" = ON |
Bit | 0 | Application | 166 |
| SWCi_O6140_c_sfr | 0x105F | CANopen Object 6140, emergency vehicle warning light command, right side turn signal: "0" = OFF "1" = ON |
Bit | 0 | Application | 167 |
| SWCi_O6140_c_tlfl | 0x1060 | CANopen Object 6140, emergency vehicle warning light command, left trunk lid turn signal lamp: "0" = OFF "1" = ON |
Bit | 0 | Application | 168 |
| SWCi_O6140_c_tlfr | 0x1061 | CANopen Object 6140, emergency vehicle warning light command, right trunk lid turn signal lamp: "0" = OFF "1" = ON |
Bit | 0 | Application | 169 |
| SWCi_O6151_c_audio_mute | 0x1062 | CANopen Object 6151, hands-free system for two-way radio, audio muting: "0" = OFF "1" = ON |
Bit | 0 | Application | 170 |
| SWCi_O6151_c_indication_LE D | 0x1063 | CANopen Object 6151, hands-free system for two-way radio, LED: "0" = OFF "1" = ON |
Bit | 0 | Application | 171 |
| SWCi_Radio_Stat | 0x1064 | Status of two-way radio: "0" = OFF "1" = ON |
Bit | 0 | Application | 172 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |