Wipers, PSM Function - GF54.21-S-3044TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Windshield wiper functions
Windshield wiper module
This module must be activated in order to use the windshield wiper functions.
Heat rear window
Function requirements (AND operation)
- Module "Windshield wiper functions" has been actively configured.
- "Term15_Actv" is set (1).
- "Term61_Actv" is set (1).
Activation (AND operation)
- Function input "IN_EBL_On_Rq_MPM" is set.
- "EBL_Stat_HVAC" is set neither to "MAN_ON" nor to "ON_Rq".
Function cancellation (OR operation)
- Input is withdrawn.
- "EBL_Stat_HVAC" = "LOW_VOLT".
- "LHC_EBL_Rq" ("PN14_STAT") = 1.
Active function
- Signal "Out_MPM_EBL_On_Rq_MPM" in the signal pool is set (1).
- Configuration button has not yet been implemented.
Rear end intermittent windshield wiper switch position
Activation (AND operation)
- Function input "WprWash_Rear_Interval" is active.
- "Term15R_Actv" signal is set.
- The status of the signal "WprWash_R_Sw_Posn_V2" (electronic ignition lock (EZS) control unit (N73), "STW_ACTN_Rq") equals OFF. When the signal is set the internal request is canceled.
Function cancellation (OR operation)
- On the interior CAN (CAN B), the parameterizable special module (PSM) control unit (N26/16) receives the status signal belonging to the function ("WprWash_R_Sw_Posn_V2", "STW_ACTN_Rq"). If this signal is active (not equal to OFF), the PSM control unit cancels the request.
- Klemme15R Terminal15R OFF. The internal request remains active.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the wiper control system are canceled.
- "Out_MPM_WprWash_R_Sw_Posn_Wash_MPM_V2".
- Signal in the signal pool
"Out_MPM_WprWash_R_Sw_Posn_Interval_MPM_V2" is set (1).
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter
- None.
Rear end wash windshield wiper switch position
Activation (AND operation)
- Function input "WprWash_Rear_Wash" is active.
- "Term15R_Actv" signal is set.
- The status of the signal "WprWash_R_Sw_Posn_V2" (electronic ignition lock (EZS) control unit (N73), "STW_ACTN_Rq") equals OFF. When the signal is set the internal request is canceled.
Function cancellation (OR operation)
- On the interior CAN (CAN B), the PSM control unit receives the status signal belonging to the function ("WprWash_R_Sw_Posn_V2", "STW_ACTN_Rq"). If this signal is active (not equal to OFF), the PSM control unit cancels the request.
- Klemme15R Terminal15R OFF. The internal request remains active.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the wiper control system are canceled.
- "Out_MPM_WprWash_R_Sw_Posn_Intervall_MPM_V2".
- Signal in the signal pool
"Out_MPM_WprWash_R_Sw_Posn_Wash_MPM_V2" is set (1).
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter
- None.
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |