Sliding Roof, PSM Function - GF54.21-S-3045TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Sliding sunroof functions
Before using the module it has to be activated per coding.
| Parameter | Value range | Meaning |
|---|---|---|
| Shift_Roof_Run_After_Time | 0...255 | Run-on time after Klemme15R OFF in minutes |
| Timeout_TSSR_Switch | 0...255 | Maximum button operation period up to "Button stuck" is detected, in seconds 0: Timeout monitoring inactive |
| Timeout_TSSR_Rear_Switch | 0...255 | Maximum button operation period up to "Button stuck" is detected, in seconds 0: Timeout monitoring inactive |
Sliding sunroof software module states
Function requirements: The sliding sunroof function module is enabled (activated) per coding.
The sliding sunroof function module changes at terminal 15R ON into normal mode. At terminal 15R OFF the run-on time is started.
After terminal 15R OFF a change is made to the run-on mode. The run-on mode changes to standby.
- Expiration of run-on time.
- "CLkS_Busy_CBC" = 1.
- An installed front door is open.
In run-on mode, the control unit is not kept active, i.e. the control unit's run-on time takes priority over the basic functions.
The sliding sunroof function can be operated in both the normal and run-on modes.
Roller sunblind operated
Activation (AND operation)
- Function input "TSSR_RB_Sw_Psd_MPM" is active.
- Sliding sunroof software module is in normal or run-on mode.
- The status of the signal "TSSR_RB_Sw_Psd_OHCM_VAN" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is not set. When the signal is set the internal request is canceled.
Function cancellation (OR operation)
- The status of the signal "TSSR_RB_Sw_Psd_OHCM_VAN" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is not set. When the signal is set the internal request is canceled.
- Sliding sunroof software module in standby. The internal request is canceled.
- Input is withdrawn.
- Timeout period for "Button stuck" expired. The internal request is canceled.
Active function
- Signal in "Out_MPM_TSSR_RB_Sw_Psd_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter
- Timeout period "Timeout_TSSR_Switch" for "Front sliding sunroof" switch.
Rear passenger compartment roller sunblind operated
Activation (AND operation)
- Function input "TSSR_RB_Sw_Psd_MPM" is active.
- Sliding sunroof software module is in normal or run-on mode.
- The status of the signal "TSSR_RB_Sw_Psd_OHCM_VAN" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is not set. When the signal is set the internal request is canceled.
- The status of the signal "TSSR_R_RB_Sw_Psd_R" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is "not pressed" ("NPSD"). When the signal is set the internal request is canceled.
Function cancellation (OR operation)
- The status of the signal "TSSR_R_RB_Sw_Psd_OHCM" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is set. When the signal is set the internal request is canceled.
- The status of the signal "TSSR_R_RB_Sw_Psd_R" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is not equal to "not pressed" ("NPSD"). When the signal is set the internal request is canceled. Terminal 15R is OFF. The internal request is canceled.
- Sliding sunroof software module is in normal or run-on mode.
- Input is withdrawn.
- Timeout period for "Button stuck" expired. The internal request is canceled.
Active function
- Signal in "Out_MPM_TSSR_RB_Sw_Psd_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter
- Timeout period "Timeout_TSSR_Switch" for "Front sliding sunroof" switch.
Open lifting roof
Activation (AND operation)
- Function input "TSSR_Opn_Rq_MPM" is active.
- Signal "Term15R_Actv" is set.
- The status of the signal "TSSR_Sw_Stat" (Panoramic sliding sunroof drive unit (M12), "TSSR_A1") is "not pressed" ("NPSD"). When the signal is set the internal request is canceled.
- The status of the signal "TSSR_Sw_Stat_OHCM" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is "not pressed" ("NPSD"). When the signal is set the internal request is canceled.
Function cancellation (OR operation)
- The status of the signal "TSSR_Sw_Stat" (Panoramic sliding sunroof drive unit (M12), "TSSR_A1") is not equal to "not pressed" ("NPSD"). The internal request is canceled.
- The status of the signal "TSSR_Sw_Stat_OHCM" (Overhead control panel (OCP) control unit (N70), "OHCM_A1_VAN") is not equal to "not pressed" ("NPSD"). The internal request is canceled.
- Terminal 15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following signals set for the sliding sunroof control are canceled.
- "Out_MPM_TSSR_Opn_Rq_MPM"
- "Out_MPM_TSSR_Cls_Rq_MPM"
- "Out_MPM_TSSR_Sp_Rq"
- Signal in "Out_MPM_TSSR_Opn_Rq_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter
- None.
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |