Power Windows, PSM Function - GF54.21-S-3043TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Window lifter function
Window lifter module (Power Window)
This module has to be activated to be used.
Automatically open left rear window
Activation (AND operation)
- Function input "PW_Adj_RL_AUTOOPN".
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RL_Dr_FL" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R is switched off. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RL_Man_Open_MPM"
- "Out_MPM_PW_Adj_RL_Man_Close_MPM"
- "Out_MPM_PW_Adj_RL_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RL_Auto_Open_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Automatically close left rear window
Activation (AND operation)
- Function input "PW_Adj_RL_AUTOCLS"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RL_Dr_FL" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Terminal 15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RL_Man_Open_MPM"
- "Out_MPM_PW_Adj_RL_Man_Close_MPM"
- "Out_MPM_PW_Adj_RL_Auto_Open_MPM"
- Signal in the "Out_MPM_PW_Adj_RL_Auto_Close_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Manually open left rear window.
Activation (AND operation)
- Function input "PW_Adj_RL_MANOPN"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RL_Dr_FL" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Terminal 15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RL_Auto_Open_MPM"
- "Out_MPM_PW_Adj_RL_Man_Close_MPM"
- "Out_MPM_PW_Adj_RL_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RL_Man_Open_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Manually close left rear window
Activation (AND operation)
- Function input "PW_Adj_RL_MANCLS"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RL_Dr_FL" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RL_Man_Open_MPM"
- "Out_MPM_PW_Adj_RL_Auto_Open_MPM"
- "Out_MPM_PW_Adj_RL_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RL_Man_Close_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter:
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Automatically open right rear window.
Activation (AND operation)
- Function input "PW_Adj_RR_AUTOOPN"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RR_Dr_FR" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RR_Man_Open_MPM"
- "Out_MPM_PW_Adj_RR_Man_Close_MPM"
- "Out_MPM_PW_Adj_RR_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RR_Auto_Open_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Automatically close right rear window
Activation (AND operation)
- Function input "PW_Adj_RR_AUTOCLS"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RR_Dr_FR" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RR_Man_Open_MPM"
- "Out_MPM_PW_Adj_RR_Man_Close_MPM"
- "Out_MPM_PW_Adj_RR_Auto_Open_MPM"
- Signal in the "Out_MPM_PW_Adj_RR_Auto_Close_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Manually open right rear window.
Activation (AND operation)
- Function input "PW_Adj_RR_MANOPN"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RR_Dr_FR" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RR_Auto_Open_MPM"
- "Out_MPM_PW_Adj_RR_Man_Close_MPM"
- "Out_MPM_PW_Adj_RR_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RR_Man_Open_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
Manually close right rear window
Activation (AND operation)
- Function input "PW_Adj_RR_MANCLS"
- "Term15R_Actv" signal is set.
- The status of the "PW_Adj_RR_Dr_FR" signal contains the "not pressed" ("NPSD") value. When the signal is set, the internal request is canceled.
Function cancellation (OR operation)
- Klemme15R OFF. The internal request is canceled.
- Input is withdrawn.
Active function
- Only plausible switch positions are sent. The following set signals and internal requests from the window lifter control system are canceled.
- "Out_MPM_PW_Adj_RR_Man_Open_MPM"
- "Out_MPM_PW_Adj_RR_Auto_Open_MPM"
- "Out_MPM_PW_Adj_RR_Auto_Close_MPM"
- Signal in the "Out_MPM_PW_Adj_RR_Man_Close_MPM" signal pool is set (1).
- If the internal request is canceled, the input has to be actuated again in order to activate.
Parameter
- None
- No check is performed because no CAN signal has been received from the left front door control unit.
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |