LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Metris Van Cargo >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instruments (03 Of 11) -- 447 Chassis >> Basic Knowledge >> Output Signal List, PSM Function - GF54.21-S-3102TRA

Output Signal List, PSM Function - GF54.21-S-3102TRA

Model 447 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

Model 448 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

IMPORTANT Signal identification number = Signal ID.

OUTPUT SIGNAL LIST, PSM FUNCTION

Signal name Signal ID Description Signal type Default value Input information Signal number
MFA_01_Load_detect 0x1075 Load detection status
"1" = Load present
Bit 0 Output monitoring 193
MFA_01_Overl_Cutoff_Stat 0x1076 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 194
MFA_01_Stat 0x1077 Feedback line status
"1" = Output active
Bit 0 Output monitoring 195
MFA_02_Load_detect 0x1078 Load detection status
"1" = Load present
Bit 0 Output monitoring 196
MFA_02_Overl_Cutoff_Stat 0x1079 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 197
MFA_02_Stat 0x107A Feedback line status
"1" = Output active
Bit 0 Output monitoring 198
MFA_03_Load_detect 0x107B Load detection status
"1" = Load present
Bit 0 Output monitoring 199
MFA_03_Overl_Cutoff_Stat 0x107C Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 200
MFA_03_Stat 0x107D Feedback line status
"1" = Output active
Bit 0 Output monitoring 201
MFA_03_VoltL_Rq 0x107E Not used Bit 0 Output monitoring 202
MFA_04_Load_detect 0x107F Load detection status
"1" = Load present
Bit 0 Output monitoring 203
MFA_04_Overl_Cutoff_Stat 0x1080 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 204
MFA_04_Stat 0x1081 Feedback line status
"1" = Output active
Bit 0 Output monitoring 205
MFA_05_Load_detect 0x1082 Load detection status
"1" = Load present
Bit 0 Output monitoring 206
MFA_05_Overl_Cutoff_Stat 0x1083 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 207
MFA_05_Stat 0x1084 Feedback line status
"1" = Output active
Bit 0 Output monitoring 208
MFA_06_Overl_Cutoff_Stat 0x1085 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 209
MFA_06_Stat 0x1086 Feedback line status
"1" = Output active
Bit 0 Output monitoring 210
MFA_07_Overl_Cutoff_Stat 0x1087 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 211
MFA_07_Stat 0x1088 Feedback line status
"1" = Output active
Bit 0 Output monitoring 212
MFA_08_Overl_Cutoff_Stat 0x1089 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 213
MFA_08_Stat 0x108A Feedback line status
"1" = Output active
Bit 0 Output monitoring 214
MFA_09_Overl_Cutoff_Stat 0x108B Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 215
MFA_09_Stat 0x108C Feedback line status
"1" = Output active
Bit 0 Output monitoring 216
MFA_10_Overl_Cutoff_Stat 0x108D Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 217
MFA_11_Overl_Cutoff_Stat 0x108F Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 219
MFA_11_Stat 0x1090 Feedback line status
"1" = Output active
Bit 0 Output monitoring 220
MFA_12_Overl_Cutoff_Stat 0x1091 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 221
MFA_12_Stat 0x1092 Feedback line status
"1" = Output active
Bit 0 Output monitoring 222
MFA_13_Overl_Cutoff_Stat 0x1093 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 223
MFA_13_Stat 0x1094 Feedback line status
"1" = Output active
Bit 0 Output monitoring 224
MFA_14_Overl_Cutoff_Stat 0x1095 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 225
MFA_14_Stat 0x1096 Feedback line status
"1" = Output active
Bit 0 Output monitoring 226
MFA_15_Overl_Cutoff_Stat 0x1097 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 227
MFA_16_Overl_Cutoff_Stat 0x1098 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 228
MFA_16_Stat 0x1099 Feedback line status
"1" = Output active
Bit 0 Output monitoring 229
MFA_17_Overl_Cutoff_Stat 0x109A Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 230
MFA_17_Stat 0x109B Feedback line status
"1" = Output active
Bit 0 Output monitoring 231
MFA_18_Load_detect 0x109C Load detection status
"1" = Load present
Bit 0 Output monitoring 232
MFA_18_Overl_Cutoff_Stat 0x109D Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 233
MFA_18_Stat 0x109E Feedback line status
"1" = Output active
Bit 0 Output monitoring 234
MFA_19_Load_detect 0x109F Load detection status
"1" = Load present
Bit 0 Output monitoring 235
MFA_19_Overl_Cutoff_Stat 0x10A0 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 236
MFA_19_Stat 0x10A1 Feedback line status
"1" = Output active
Bit 0 Output monitoring 237
MFA_20_Load_detect 0x10A2 Load detection status
"1" = Load present
Bit 0 Output monitoring 238
MFA_20_Overl_Cutoff_Stat 0x10A3 Overload cutoff status
"1" = Cutoff active
Bit 0 Output monitoring 239
MFA_20_Stat 0x10A4 Feedback line status
"1" = Output active
Bit 0 Output monitoring 240
MFA_02_Wake-up 0x1221 Output MFA_02 has activated the control unit. Bit 0 Digital input 731
MFA_08_Wake-up 0x1222 Output MFA_08 has activated the control unit. Bit 0 Digital input 732
MFA_09_Wake-up 0x1223 Output MFA_09 has activated the control unit. Bit 0 Digital input 733
MFA_10_Wake-up 0x1224 Output MFA_10 has activated the control unit. Bit 0 Digital input 734
  Parameterizable special module (PSM) control unit component description   GF54.21-S-5005TRA
  Overview of system components for parameterizable special module (PSM)   GF54.21-S-9998TRA