Input Signal List, PSM Function - GF54.21-S-3101TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
INPUT SIGNAL LIST, PSM FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| MFE_01 | 0x1002 | Digital status of analog input MFE_01 Evaluation with hysteresis |
Bit | 0 | Analog/digital converter | 9 |
| MFE_01_analog | 0x3002 | Voltage value of analog input MFE_01 in 1 mV/bit |
Data item (Word) | 0 | Analog/digital converter | 10 |
| MFE_01_rel | 0x2002 | Analog input MFE_01, relative voltage value depending on terminal 30 voltage in 1 %/bit | Byte | 0 | Analog/digital converter | 11 |
| MFE_01_Stufe_1 | 0x1003 | Stage 1 of threshold value evaluation, analog input MFE_01 | Bit | 0 | Analog/digital converter | 12 |
| MFE_01_Stufe_2 | 0x1004 | Stage 2 of threshold value evaluation, analog input MFE_01 | Bit | 0 | Analog/digital converter | 13 |
| MFE_01_Stufe_3 | 0x1005 | Stage 3 of threshold value evaluation, analog input MFE_01 | Bit | 0 | Analog/digital converter | 14 |
| MFE_01_Stufe_4 | 0x1006 | Stage 4 of threshold value evaluation, analog input MFE_01 | Bit | 0 | Analog/digital converter | 15 |
| MFE_02 | 0x1007 | Digital status of high-active input MFE_02 | Bit | 0 | Digital input | 16 |
| MFE_03 | 0x1008 | Digital status of high-active input MFE_03 | Bit | 0 | Digital input | 17 |
| MFE_04 | 0x1009 | Digital status of high-active input MFE_04 | Bit | 0 | Digital input | 18 |
| MFE_05 | 0x100A | Digital status of low-active input MFE_05 | Bit | 0 | Digital input | 19 |
| MFE_06 | 0x100B | Digital status of low-active input MFE_06 | Bit | 0 | Digital input | 20 |
| MFE_07 | 0x100C | Digital status of low-active input MFE_07 | Bit | 0 | Digital input | 21 |
| MFE_08 | 0x100D | Digital status of analog input MFE_08 Evaluation with hysteresis |
Bit | 0 | Analog/digital converter | 22 |
| MFE_08_analog | 0x3003 | Voltage value of the analog input MFE_08 in 1 mV/bit | Data item (Word) | 0 | Analog/digital converter | 23 |
| MFE_08_rel | 0x2003 | Analog input MFE_08, relative voltage value depending on terminal 30 voltage in 1 %/bit | Byte | 0 | Analog/digital converter | 24 |
| MFE_08_Stufe_1 | 0x100E | Stage 1 of threshold value evaluation, analog input MFE_08 | Bit | 0 | Analog/digital converter | 25 |
| MFE_08_Stufe_2 | 0x100F | Stage 2 of threshold value evaluation, analog input MFE_08 | Bit | 0 | A/D converter | 26 |
| MFE_08_Stufe_3 | 0x1010 | Stage 3 of threshold value evaluation, analog input MFE_08 | Bit | 0 | Analog/digital converter | 27 |
| MFE_08_Stufe_4 | 0x1011 | Stage 4 of threshold value evaluation, analog input MFE_08 | Bit | 0 | Analog/digital converter | 28 |
| MFE_08_Ueberwachung_ok | 0x1012 | Error signaling of button monitoring | Bit | 0 | Fault monitoring | 29 |
| MFE_09 | 0x1013 | Digital status of analog input MFE_09 Evaluation with hysteresis |
Bit | 0 | Analog/digital converter | 30 |
| MFE_09_analog | 0x3004 | Voltage value of analog input MFE_09 in 1 mV/bit |
Data item (Word) | 0 | Analog/digital converter | 31 |
| MFE_09_rel | 0x2004 | Analog input MFE_09, relative voltage value depending on terminal 30 voltage in 1 %/bit | Byte | 0 | Analog/digital converter | 32 |
| MFE_09_Stufe_1 | 0x1014 | Stage 1 of threshold value evaluation, analog input MFE_09 | Bit | 0 | Analog/digital converter | 33 |
| MFE_09_Stufe_2 | 0x1015 | Stage 2 of threshold value evaluation, analog input MFE_09 | Bit | 0 | Analog/digital converter | 34 |
| MFE_09_Stufe_3 | 0x1016 | Stage 3 of threshold value evaluation, analog input MFE_09 | Bit | 0 | Analog/digital converter | 35 |
| MFE_09_Stufe_4 | 0x1017 | Stage 4 of threshold value evaluation, analog input MFE_09 | Bit | 0 | Analog/digital converter | 36 |
| MFE_09_Ueberwachung_ok | 0x1018 | Error signaling of button monitoring | Bit | 0 | Fault monitoring | 37 |
| MFE_10 | 0x1019 | Digital status of analog input MFE_10 Evaluation with hysteresis |
Bit | 0 | Analog/digital converter | 38 |
| MFE_10_analog | 0x3005 | Voltage value of analog input MFE_10 in 1 mV/bit |
Data item (Word) | 0 | Analog/digital converter | 39 |
| MFE_10_rel | 0x2005 | Analog input MFE_10, relative voltage value depending on terminal 30 voltage in 1 %/bit | Byte | 0 | Analog/digital converter | 40 |
| MFE_10_Stufe_1 | 0x101A | Stage 1 of threshold value evaluation, analog input MFE_10 | Bit | 0 | Analog/digital converter | 41 |
| MFE_10_Stufe_2 | 0x101B | Stage 2 of threshold value evaluation, analog input MFE_10 | Bit | 0 | Analog/digital converter | 42 |
| MFE_10_Stufe_3 | 0x101C | Stage 3 of threshold value evaluation, analog input MFE_10 | Bit | 0 | Analog/digital converter | 43 |
| MFE_10_Stufe_4 | 0x101D | Stage 4 of threshold value evaluation, analog input MFE_10 | Bit | 0 | Analog/digital converter | 44 |
| MFE_01_inv | 0x120D | Digital status of analog input MFE_01 Evaluation with hysteresis, logically inverted |
Bit | 0 | Analog/digital converter | 710 |
| MFE_02_inv | 0x120E | Digital status of high-active input MFE_02 logically inverted |
Bit | 0 | Digital input | 711 |
| MFE_03_inv | 0x120F | Digital status of high-active input MFE_03 logically inverted |
Bit | 0 | Digital input | 712 |
| MFE_04_inv | 0x1210 | Digital status of high-active input MFE_04 logically inverted |
Bit | 0 | Digital input | 713 |
| MFE_05_inv | 0x1211 | Digital status of low-active input MFE_05 logically inverted |
Bit | 0 | Digital input | 714 |
| MFE_06_inv | 0x1212 | Digital status of low-active input MFE_06 logically inverted |
Bit | 0 | Digital input | 715 |
| MFE_07_inv | 0x1213 | Digital status of low-active input MFE_07 logically inverted |
Bit | 0 | Digital input | 716 |
| MFE_08_inv | 0x1214 | Digital status of analog input MFE_08 Evaluation with hysteresis, logically inverted |
Bit | 0 | Analog/digital converter | 717 |
| MFE_09_inv | 0x1215 | Digital status of analog input MFE_09 Evaluation with hysteresis, logically inverted, i.e. high active |
Bit | 0 | Analog/digital converter | 718 |
| MFE_10_inv | 0x1216 | Digital status of analog input MFE_10 Evaluation with hysteresis, logically inverted, i.e. high active |
Bit | 0 | Analog/digital converter | 719 |
| MFE_02_wakeup | 0x121A | Input MFE_02 has woken up the control unit. | Bit | 0 | Digital input | 724 |
| MFE_03_wakeup | 0x121B | Input MFE_03 has woken up the control unit. | Bit | 0 | Digital input | 725 |
| MFE_04_wakeup | 0x121C | Input MFE_04 has woken up the control unit. | Bit | 0 | Digital input | 726 |
| MFE_05_wakeup | 0x121D | Input MFE_05 has woken up the control unit. | Bit | 0 | Digital input | 727 |
| MFE_06_wakeup | 0x121E | Input MFE_06 has woken up the control unit. | Bit | 0 | Digital input | 728 |
| MFE_07_wakeup | 0x121F | Input MFE_07 has woken up the control unit. | Bit | 0 | Digital input | 729 |
| MFE_08_wakeup | 0x1220 | Input MFE_08 has woken up the control unit. | Bit | 0 | Digital input | 730 |
| MFE_08_Open_Load | 0x1331 | Input MFE_08 has detected a break. This signal is only used for a configured alarm button on MFE_08. |
Bit | 0 | Fault monitoring | 1229 |
| MFE_08_Sticking_Key | 0x1332 | Input MFE_08 has detected a sticking switch This signal is only used for a configured alarm switch on MFE_08. |
Bit | 0 | Fault monitoring | 1230 |
| MFE_09_Open_Load | 0x1333 | Input MFE_09 has detected a break This signal is only used for a configured alarm reset button on MFE_09. |
Bit | 0 | Fault monitoring | 1231 |
| MFE_09_Sticking_Key | 0x1334 | Input MFE_09 has detected a break This signal is only used for a configured alarm reset button on MFE_09. |
Bit | 0 | Fault monitoring | 1232 |
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||
| Overview of system components for parameterizable special module (PSM) | GF54.21-S-9998TRA |