Signal name Signal ID Description Signal type Default value Input information Signal number
MFE_01 0x1002 Digital status of analog input MFE_01
Evaluation with hysteresis
Bit 0 Analog/digital converter 9
MFE_01_analog 0x3002 Voltage value of analog input MFE_01
in 1 mV/bit
Data item (Word) 0 Analog/digital converter 10
MFE_01_rel 0x2002 Analog input MFE_01, relative voltage value depending on terminal 30 voltage in 1 %/bit Byte 0 Analog/digital converter 11
MFE_01_Stufe_1 0x1003 Stage 1 of threshold value evaluation, analog input MFE_01 Bit 0 Analog/digital converter 12
MFE_01_Stufe_2 0x1004 Stage 2 of threshold value evaluation, analog input MFE_01 Bit 0 Analog/digital converter 13
MFE_01_Stufe_3 0x1005 Stage 3 of threshold value evaluation, analog input MFE_01 Bit 0 Analog/digital converter 14
MFE_01_Stufe_4 0x1006 Stage 4 of threshold value evaluation, analog input MFE_01 Bit 0 Analog/digital converter 15
MFE_02 0x1007 Digital status of high-active input MFE_02 Bit 0 Digital input 16
MFE_03 0x1008 Digital status of high-active input MFE_03 Bit 0 Digital input 17
MFE_04 0x1009 Digital status of high-active input MFE_04 Bit 0 Digital input 18
MFE_05 0x100A Digital status of low-active input MFE_05 Bit 0 Digital input 19
MFE_06 0x100B Digital status of low-active input MFE_06 Bit 0 Digital input 20
MFE_07 0x100C Digital status of low-active input MFE_07 Bit 0 Digital input 21
MFE_08 0x100D Digital status of analog input MFE_08
Evaluation with hysteresis
Bit 0 Analog/digital converter 22
MFE_08_analog 0x3003 Voltage value of the analog input MFE_08 in 1 mV/bit Data item (Word) 0 Analog/digital converter 23
MFE_08_rel 0x2003 Analog input MFE_08, relative voltage value depending on terminal 30 voltage in 1 %/bit Byte 0 Analog/digital converter 24
MFE_08_Stufe_1 0x100E Stage 1 of threshold value evaluation, analog input MFE_08 Bit 0 Analog/digital converter 25
MFE_08_Stufe_2 0x100F Stage 2 of threshold value evaluation, analog input MFE_08 Bit 0 A/D converter 26
MFE_08_Stufe_3 0x1010 Stage 3 of threshold value evaluation, analog input MFE_08 Bit 0 Analog/digital converter 27
MFE_08_Stufe_4 0x1011 Stage 4 of threshold value evaluation, analog input MFE_08 Bit 0 Analog/digital converter 28
MFE_08_Ueberwachung_ok 0x1012 Error signaling of button monitoring Bit 0 Fault monitoring 29
MFE_09 0x1013 Digital status of analog input MFE_09
Evaluation with hysteresis
Bit 0 Analog/digital converter 30
MFE_09_analog 0x3004 Voltage value of analog input MFE_09
in 1 mV/bit
Data item (Word) 0 Analog/digital converter 31
MFE_09_rel 0x2004 Analog input MFE_09, relative voltage value depending on terminal 30 voltage in 1 %/bit Byte 0 Analog/digital converter 32
MFE_09_Stufe_1 0x1014 Stage 1 of threshold value evaluation, analog input MFE_09 Bit 0 Analog/digital converter 33
MFE_09_Stufe_2 0x1015 Stage 2 of threshold value evaluation, analog input MFE_09 Bit 0 Analog/digital converter 34
MFE_09_Stufe_3 0x1016 Stage 3 of threshold value evaluation, analog input MFE_09 Bit 0 Analog/digital converter 35
MFE_09_Stufe_4 0x1017 Stage 4 of threshold value evaluation, analog input MFE_09 Bit 0 Analog/digital converter 36
MFE_09_Ueberwachung_ok 0x1018 Error signaling of button monitoring Bit 0 Fault monitoring 37
MFE_10 0x1019 Digital status of analog input MFE_10
Evaluation with hysteresis
Bit 0 Analog/digital converter 38
MFE_10_analog 0x3005 Voltage value of analog input MFE_10
in 1 mV/bit
Data item (Word) 0 Analog/digital converter 39
MFE_10_rel 0x2005 Analog input MFE_10, relative voltage value depending on terminal 30 voltage in 1 %/bit Byte 0 Analog/digital converter 40
MFE_10_Stufe_1 0x101A Stage 1 of threshold value evaluation, analog input MFE_10 Bit 0 Analog/digital converter 41
MFE_10_Stufe_2 0x101B Stage 2 of threshold value evaluation, analog input MFE_10 Bit 0 Analog/digital converter 42
MFE_10_Stufe_3 0x101C Stage 3 of threshold value evaluation, analog input MFE_10 Bit 0 Analog/digital converter 43
MFE_10_Stufe_4 0x101D Stage 4 of threshold value evaluation, analog input MFE_10 Bit 0 Analog/digital converter 44
MFE_01_inv 0x120D Digital status of analog input MFE_01
Evaluation with hysteresis, logically inverted
Bit 0 Analog/digital converter 710
MFE_02_inv 0x120E Digital status of high-active input MFE_02
logically inverted
Bit 0 Digital input 711
MFE_03_inv 0x120F Digital status of high-active input MFE_03
logically inverted
Bit 0 Digital input 712
MFE_04_inv 0x1210 Digital status of high-active input MFE_04
logically inverted
Bit 0 Digital input 713
MFE_05_inv 0x1211 Digital status of low-active input MFE_05
logically inverted
Bit 0 Digital input 714
MFE_06_inv 0x1212 Digital status of low-active input MFE_06
logically inverted
Bit 0 Digital input 715
MFE_07_inv 0x1213 Digital status of low-active input MFE_07
logically inverted
Bit 0 Digital input 716
MFE_08_inv 0x1214 Digital status of analog input MFE_08
Evaluation with hysteresis, logically inverted
Bit 0 Analog/digital converter 717
MFE_09_inv 0x1215 Digital status of analog input MFE_09
Evaluation with hysteresis, logically inverted, i.e. high active
Bit 0 Analog/digital converter 718
MFE_10_inv 0x1216 Digital status of analog input MFE_10
Evaluation with hysteresis, logically inverted, i.e. high active
Bit 0 Analog/digital converter 719
MFE_02_wakeup 0x121A Input MFE_02 has woken up the control unit. Bit 0 Digital input 724
MFE_03_wakeup 0x121B Input MFE_03 has woken up the control unit. Bit 0 Digital input 725
MFE_04_wakeup 0x121C Input MFE_04 has woken up the control unit. Bit 0 Digital input 726
MFE_05_wakeup 0x121D Input MFE_05 has woken up the control unit. Bit 0 Digital input 727
MFE_06_wakeup 0x121E Input MFE_06 has woken up the control unit. Bit 0 Digital input 728
MFE_07_wakeup 0x121F Input MFE_07 has woken up the control unit. Bit 0 Digital input 729
MFE_08_wakeup 0x1220 Input MFE_08 has woken up the control unit. Bit 0 Digital input 730
MFE_08_Open_Load 0x1331 Input MFE_08 has detected a break.
This signal is only used for a configured alarm button on MFE_08.
Bit 0 Fault monitoring 1229
MFE_08_Sticking_Key 0x1332 Input MFE_08 has detected a sticking switch
This signal is only used for a configured alarm switch on MFE_08.
Bit 0 Fault monitoring 1230
MFE_09_Open_Load 0x1333 Input MFE_09 has detected a break
This signal is only used for a configured alarm reset button on MFE_09.
Bit 0 Fault monitoring 1231
MFE_09_Sticking_Key 0x1334 Input MFE_09 has detected a break
This signal is only used for a configured alarm reset button on MFE_09.
Bit 0 Fault monitoring 1232
  Parameterizable special module (PSM) control unit component description   GF54.21-S-5005TRA