Functional Scope Of Global Functions, PSM, Function - GF54.21-S-3009TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Starter lockout
Activation (AND operation):
- Function input "SSA_Dsbl_Rq_MPM" is active
- "Term15_Actv" signal is set
Function cancellation (OR operation):
- "Term15_Actv" signal is switched off. The internal request remains active.
- Input is withdrawn.
Active function:
- Signal in signal pool "Out_MPM_SSA_Dsbl_Rq_MPM" is set ("1")
- If the internal request is canceled, the input has to be activated by operating again.
Parameter:
- None
To be clarified:
- Function was derived from K matrix. Function description not available in component requirement specification.
PSM display message
Activation (AND operation):
- Function input "MPM_MsgDisp_Rq" is active
Function cancellation (OR operation):
- Input is withdrawn.
Active function:
- Signal in signal pool "Out_MPM_MPM_MsgDisp_Rq" is set ("1")
- If the internal request is canceled, the input has to be activated by operating again.
Parameter:
- None
To be clarified:
- Signal is set or canceled. No support provided for byte information.
This signal is no longer used and it has been replaced. The send signals from the interior CAN (CAN B) "MPM_Msg1_Disp_Rq" to "MPM_Msg29_Disp_Rq" are available for the display message request.
Switch on front interior lighting
Activation (AND operation):
- Function input "IL_F_On_Rq_MPM" is active
Function cancellation (OR operation):
- Input is canceled if the message time of min. 5 messages has expired.
- Timeout for 5 messages.
Active function:
- Signal in signal pool "Out_MPM_IL_F_On_Rq_MPM" is set ("1") for approx. 5 messages to active, even when the input was canceled in the meantime.
- If the internal request is canceled, the input has to be activated by operating again.
If the "Out_MPM_IL_F_On_Rq_MPM" signal is changed, CAN B is woken-up and kept awake for 5 to 7 s.
Parameter:
- None
- The receiver control unit evaluates the signal change from 0 to 1 and toggles the interior lighting function.
- Only the switch-on edge is evaluated in the parameterizable special module (PSM) control unit (N26/16)
| Parameterizable special module (PSM) control unit component description | GF54.21-S-5005TRA | ||