Alarm Lighting Signal List, PSM Function - GF54.21-S-3104TRA
Model 447
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Model 448
With Code ED5 (Parameterisable special module)
Except Code XM7 (MOPF II)
Signal identification number = Signal ID.
| Signal name | Signal ID | Description | Signal type | Default value | Input information | Signal number |
|---|---|---|---|---|---|---|
| Out_MPM_CLkS_Lk_Rq | 0x12DE | Central locking system locking request | Bit | 0 | Application | 1141 |
| Out_MPM_IL_On_Rq | 0x12DF | Switch on interior lighting | Bit | 0 | Application | 1142 |
| Out_MPM_RecircAir_On_Rq | 0x12E0 | Switch on recirculated air | Bit | 0 | Application | 1143 |
| Out_MPM_TaxiEmgCall_Rq | 0x12E1 | Send radio help call request | Bit | 0 | Application | 1144 |
| Out_MPM_TurnInd_On_Rq | 0x12E2 | Switch on turn signal | Bit | 0 | Application | 1145 |
| Out_MPM_Hrn_On_Rq_Alm | 0x12E3 | Switch on horn | Bit | 0 | Application | 1146 |
| Out_MPM_LgtTmOutDsabl_Rq | 0x12E4 | Switch off automatic shutoff (time out) for light actuations | Bit | 0 | Application | 1147 |
| Out_MPM_TumlndHiPrio_Rq | 0x12E5 | Set turn signal request to high priority | Bit | 0 | Application | 1148 |
| Out_MPM_TurnLmpOnTm | 0x2098 | Duration of turn signal light phase | Byte | 0 | Application | 1149 |
| Out_MPM_HrnOnDur | 0x2099 | Horn duration | Byte | 0 | Application | 1150 |
| Out_MPM_EmgAlmTmSeg_1 | 0x209A | Emergency alarm time segment 1 | Byte | 0 | Application | 1151 |
| Out_MPM_EmgAlmTmSeg_2 | 0x209B | Emergency alarm time segment 2 | Byte | 0 | Application | 1152 |
| Out_MPM_FogLmp_TmSeg_1_On_Rq | 0x12E6 | Switch on rear fog light in time segment 1 | Bit | 0 | Application | 1153 |
| Out_MPM_HiBm_TmSeg_1_On_Rq | 0x12E7 | Switch on high beam in time segment 1 | Bit | 0 | Application | 1154 |
| Out_MPM_LoBm_TmSeg_1_On_Rq | 0x12E8 | Switch on low beam in time segment 1 | Bit | 0 | Application | 1155 |
| Out_MPM_TlLmp_TmSeg_1_On_Rq | 0x12E9 | Switch on tail light in time segment 1 request | Bit | 0 | Application | 1156 |
| Out_MPM_FogLmp_TmSeg_2_On_Rq | 0x12EA | Switch on rear fog light in time segment 2 | Bit | 0 | Application | 1157 |
| Out_MPM_HiBm_TmSeg_2_On_Rq | 0x12EB | Switch on high beam in time segment 2 | Bit | 0 | Application | 1158 |
| Out_MPM_LoBm_TmSeg_2_On_Rq | 0x12EC | Switch on low beam in time segment 2 | Bit | 0 | Application | 1159 |
| Out_MPM_TlLmp_TmSeg_2_On_Rq | 0x12ED | Switch on tail light in time segment 2 request | Bit | 0 | Application | 1160 |