LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Metris Van Cargo >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System -- Body (2 Of 6) -- 447 Chassis >> Testing & Repair >> Perform Function Test For Rain/Light Sensor - AR82.00-S-0020-01S

Perform Function Test For Rain/Light Sensor - AR82.00-S-0020-01S

Model 415 

With Code JA5 (Light and rain sensor) 

Model 447, 448 

With Code JF1 (rain sensor) 

Model 447, 448 

With Code LA2 (Headlamp Assist) 

Model 447, 448 

With Code LG2 (LED Intelligent Light System) 

Model 636, 639 

With Code JA5 (Light and rain sensor) 

Model 900, 906 

With Code JA5 (Light and rain sensor) 

Model 907, 910 

Shown On Model 639 

  1. Switch on ignition.

    IMPORTANT Leave ignition switched on for at least 5 s.

  2. Switch off ignition.

    IMPORTANT Leave ignition switched off for at least 5 s. Measuring field of the windshield is calibrated in the humidity sensor/light sensor/rain sensor (B38/2) and the measurement values stored.

    G16488430Courtesy of MERCEDES-BENZ USA
  3. Turn on ignition.
  4. Set combination switch to intermittent mode "I".
  5. Wet windshield with a little water in vicinity of humidity sensor/light sensor/rain sensor (B38/2).

    IMPORTANT Windshield wiper must switch itself on.

  6. Set rotary light switch to "AUTO".
  7. Cover humidity sensor/light sensor/rain sensor (B38/2).

    IMPORTANT Exterior lights must switch on automatically.