Checking Wiring Harness - AR54.18-D-0600-01A
Model All (Heavy transporter, Light transporter)
| Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100°C or 212°F. Disconnect current supply when working on such component parts. |
AS91.00-Z-0008-01A |
Connect electrical connection kit to control unit electrical connector and squib electrical connector according to wiring diagram using test cable.
An appropriate test cable must be used in combination with
Test box for tests of electric lines from the supplemental restraint system.
There is the possibility of airbag and emergency tensioning retractor actuation.
- Check resistance of lines according to wiring diagram using a continuity tester.
The resistance must be < 0.5 Ω.