LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Maybach GLS600 >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Electrical System, Equipment & Instruments - 167 Chassis (2 Of 4) >> Testing & Repair >> Check On-Board Electrical System Battery For 48 Volt On-Board Electrical System, When Removed, For Transportability - AR54.10-P-0048ME

Check On-Board Electrical System Battery For 48 Volt On-Board Electrical System, When Removed, For Transportability - AR54.10-P-0048ME

Model All (CAR) 

With Code B01 (48V technology) 

G14799027Courtesy of MERCEDES-BENZ USA
DANGER Risk of fire  /risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning  caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. AS54.10-Z-0001-01A
Notice  General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment   AH00.00-Z-0300-01A
Notice  Notes on battery   AH54.10-P-0001-01A
  Notes on safety-relevant components   AH00.00-Z-0019-01A
INSPECT Check     
1 Print out analysis sheet.    
REFER TO FORMS Analysis sheet for lithium-ion battery 48 V, form Model 167, 205, 206, 213, 223, 232, 238, 253, 254, 257, 290
with code B01 (48V technology)
OF54.10-P-3000-15FR 
2 Check hazard potential of on-board electrical system battery (2). When replacing the on-board electrical system battery (2).  
      AR47.70-P-0017-01A
    IMPORTANT In the event of smoke generation or fire, the fire department must be notified.
IMPORTANT The analysis sheet must be used to check whether the on-board electrical system battery (2) presents an acute hazard.
 
3 Check housing of on-board electrical system battery (2) for mechanical damage.   AR47.70-P-0017-02A
  1 IMPORTANT The analysis sheet must be used to check whether there is damage to the on-board electrical system battery (2) causing electrolyte to leak out. If there is an electrolyte leakage.

Notify MPC/general representative.
 
4 Connect test box (1) to on-board electrical system battery (2).    
REFER TO SPECIAL TOOLS 000 588 08 19 00 Test box Model 118, 167, 177, 205, 206, 213, 218, 222, 223, 232, 238, 247, 253, 254, 257, 290, 293 with code B01 (48V technology) WS54.00-P-0069B
5 Set switch (3) to position "1". IMPORTANT The "POWER" lamp must light up.  
6 Check flash code of "TEST" lamp. IMPORTANT The "TEST' lamp flashes (1 s ON, 1 s OFF): on-board electrical system battery (2) is safe for transportation.
IMPORTANT The "TEST" lamp flashes (0.1 s ON, 1 s OFF): on-board electrical system battery (2) is not safe for transportation.
If the on-board electrical system battery (2) is not safe for transportation,

set switch (3) to position "0", disconnect test box (1) and repeat test after 70 min. If the on-board electrical system battery (2) is not safe for transportation,

contact responsible MPC/general distributor.
 
7 Set switch (3) to position "0".    
8 Disconnect test box (1).