Information On E-Active Body Control Suspension - AH32.50-P-0002-01ME
Model all (CAR)
Notes for E-ACTIVE BODY CONTROL suspension:
- The connection fittings and hose connections must be cleaned before starting the repair.
- Open connection fittings and hose connections must be sealed to prevent dirt particles from entering into the system.
- Emptying and filling the system may only be performed with the guided diagnosis.
- Before each emptying procedure, the shutoff valves of the respective shock absorber must be screwed in up to the end stop.
- Only by screwing in the shutoff valves can the hydraulic pressure in the shock absorber be retained. It is not possible to fill the shock absorbers.
- When filling the suspension system, ensure that sufficient hydraulic fluid is in the filling unit.
- Ensure absolute cleanliness when pouring in the hydraulic fluid.
- The funnel with filter that is used for adding the hydraulic fluid must not be used for other operating fluids. Store the funnel with filter in a separate cabinet.
- Due to high pressures in the E-ACTIVE BODY CONTROL, work on the system must be conducted with the utmost care.
- Hydraulic line: If the sealing ring is damaged, only the sealing ring must be replaced. If the support ring is damaged, the complete hydraulic line must be replaced.