Remove Contacts From Maxi Power Timer Coupling - AR00.19-P-0120-14A
Model All
Unfasten secondary release on version with retaining cap (shown on Maxi Power Timer, Junior Power Timer coupling)
- Using a suitable tool, pry up the lock tabs on the retaining cap (1).
- Pull the retaining cap from the clutch housing (2).
Unpin female contacts from coupling
- Insert blade holder with
clamping pliers and
j MPT blade from front side though openings at contact cavity of coupling (1).
This step compresses the spring shackles (2) on the female contact.
- A slight tug on the corresponding cable will remove the female contact (1) from the coupling.