LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> GLC300 Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - 253 Chassis 1 Of 3 >> Basic Knowledge >> Climate Control Control Unit, Component Description - GF83.40-P-2250RF

Climate Control Control Unit, Component Description - GF83.40-P-2250RF

Model 205, 253 

Shown on model 205 

G14188745Courtesy of MERCEDES-BENZ USA

Location 

The A/C control unit is located on the front side of the A/C housing on the passenger side.

Task 

The A/C control unit is responsible for the following tasks:

Reading in of sensors and signals 

The input factors are read in via the following connections:

Direct line 

The signals from the following components are read via direct lines:

AC control LIN 1 

The signals of the air quality sensor (B31) (with CODE 581 (Automatic air conditioning)) are read in over the climate control LIN 1.

Climate control LIN 2 

The signals from the high-voltage PTC heater temperature sensor (N33/5b1) (model 205.013/047/053/147/213/247/253, 253.354/954/99) are read in over the climate control LIN 2.

AC operation LIN 

The signals from the following components are read in via A/C operation LIN:

Interior CAN 

The signals are read in via the interior CAN. The functions that use these signals are described in the individual function descriptions (see block diagram or function schematic).

Evaluation of input factors 

The input factors that have been read in are evaluated by the integrated microprocessor and the relevant components are then actuated.

Actuation of components 

The actuation of the components takes place via the following connections:

Direct line 

The following components are actuated via direct lines:

205.012/013/047/053/147/212/213/247/253, 253.354/954/99 and except code B09 (Refrigerant compressor with magnetic clutch))

Interior CAN 

The signals are sent over the interior CAN.

The functions that use these signals are described in the individual function descriptions (see block diagram or function schematic).

AC control LIN 1 

The following components are actuated over the climate control LIN 1: Except CODE 581 (Automatic air conditioning):

With CODE 581 (Automatic air conditioning):

Climate control LIN 2 

The following components are actuated over the climate control LIN 2:

AC operation LIN 

The following components are actuated via climate control LIN:

  Wiring diagram for automatic air conditioning (AAC) control unit   PE83.40-P-2101-97FBA