Remove/Install Communications Module/Stationary Heater Antenna - AR82.62-P-0002LWG
Model 253
with code 348 (Emergency call/assistant system)
Model 253
with code 350 (Ecall emergency call system, Europe)
Model 253
with code B24 (Remote control for Auxiliary heating)
Fig 1: Communications Module/Stationary Heater Antenna Components Location - Model 253 With Codes 348, 350 And B24
| Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof. | No parts of the body or limbs should be within the operating area when the components are moving. | AS00.00-Z-0011-01A | |
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Notes on HANDS-FREE ACCESS | AH80.61-P-0001-01A | ||
| Remove/install | |||
| 1 | Remove right cover in load compartment at side | Model 253 (except 253.992/993) with code 350 (Ecall emergency call system, Europe) with code B24 (Remote control for Auxiliary heating) |
AR68.30-P-1180LWG |
| Model 253.992/993 with code 350 (Ecall emergency call system, Europe) with code B24 (Remote control for Auxiliary heating) |
AR68.30-P-1180RFW | ||
| 2 | Disconnect electrical connection (1) | ||
| 3 | Loosen screw/bolt (3) | ||
| 4 | Unclip retaining clip (4) of communications module/stationary heater antenna (A2/129) from bracket (2) | Fig 2 | |
| 5 | Remove communications module/stationary heater antenna (A2/129) | ||
| 6 | Install in the reverse order |