Home >> Mercedes Benz >> 2021 >> GLA45 AMG >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (Climate Control System -- 118 Chassis) >> Safety Precautions >> Risk Of Fire Due To Ignition Of R1234Yf Refrigerant On Hot Components. Risk Of Poisoning Caused By Inhaling Overheated Refrigerant Vapors. Risk Of Injury To Skin And Eyes Caused By Contact With Escaped R1234Yf Refrigerant And When Working - AS83.00-Z-0007-01A

Risk Of Fire Due To Ignition Of R1234Yf Refrigerant On Hot Components. Risk Of Poisoning Caused By Inhaling Overheated Refrigerant Vapors. Risk Of Injury To Skin And Eyes Caused By Contact With Escaped R1234Yf Refrigerant And When Working - AS83.00-Z-0007-01A

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2023 Mercedes-Benz CLA45 AMG, 2023 Mercedes-Benz CLA35 AMG, 2023 Mercedes-Benz CLA250, 2022 Mercedes-Benz CLA45 AMG, and 2022 Mercedes-Benz CLA35 AMG. However, it is still accessible from the selected car via links, so may be relevant.

Model All (4xWD, CAR, Light transporter, smart) 

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. 

Potential risks 

Fire hazard 

Refrigerant is highly flammable and in certain mixing ratios with air it is combustible. In the event of a fire, hazardous decomposition products such as, e.g. hydrogen fluoride, acyl halide, carbon monoxide (CO) and carbon dioxide (CO2 ) may develop and be released.

Risk of explosion 

Ignitable mixtures may form in combination with refrigerant vapors.

Risk of poisoning 

Refrigerant can decompose when overheated. The resulting substances are toxic and should never be inhaled. Avoid contact with skin.

Risk of suffocation 

Risk of suffocation at high concentration levels of R1234yf.

Risk of injury 

Compressed refrigerant is located in the air conditioning system lines and components. Even after the air conditioning system has been evacuated, overpressure may still be present when unfastening plug connections of the air conditioning system.

In closed air conditioning systems (filled or evacuated), high overpressure can build up due to heating which can cause the system to burst. For this reason, all welding and soldering work  on or near closed air conditioning systems is prohibited.

Risk of injury to skin and eyes caused through contact with escaped refrigerant (frostbite injuries/freezing). In the event of improperly conducted work on the refrigerant circuit, pressurized parts could present a mechanical hazard.

Contact with liquid refrigerant may cause frostbite-like damage to the skin (due to undercooling).

Health hazard 

Health hazard through inhalation of refrigerant vapors or swallowing of liquid refrigerant.

Safety instructions/precautions 

First-aid measures 

After contact with eyes: