LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> E450 Base, 2D Convertible >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - 238 Chassis (1 Of 2) >> Basic Knowledge >> Stationary Heater Control Unit, Component Description - GF83.70-P-4066FH

Stationary Heater Control Unit, Component Description - GF83.70-P-4066FH

Model 238 

up to model year 2021 

With Code 228 (Additional warm water heating) 

Shown On Model 238.3 

G15468187Courtesy of MERCEDES-BENZ USA

Location 

The stationary heater control unit is integrated in the stationary heater unit, which is located in the rear area of the right front wheel arch.

Tasks 

The stationary heater control unit has the following tasks:

Reading in of signals 

The input factors are read in via the following connections:

Direct line 

The signals from the following components are read via direct lines:

IMPORTANT If the temperature at the coolant outlet exceeds a value of T = 130 °C, the stationary heater is switched off due to overheating. If the overheating shut-off is repeated 10 times, the stationary heater is shut off followed by an overheating interlock.

Climate control LIN 2 

The stationary heater control unit also reads in the following information over the climate control LIN 2:

Evaluation of input factors 

The input factors that have been read in are evaluated by the integrated microprocessor and the relevant components are then actuated.

Actuation of components 

The following components are actuated via direct lines:

Transmitting signals 

The stationary heater control unit sends the following information or requests, among other things, via climate control LIN 2:

Variants 

Engine variants:

  Wiring diagram for stationary heater (STH) control unit   PE83.70-P-2101-97DCA