LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> CLS53 AMG >> Repair and Diagnosis >> Accessories & Equipment >> Headlights >> Electrical System - Body - 257 Chassis 4 Of 8 >> Retrofitting & Conversion >> Retrofit Electrical Lines For Instrument Cluster - AN82.85-P-0009-06FR

Retrofit Electrical Lines For Instrument Cluster - AN82.85-P-0009-06FR

Model 257 

Topical note Information on preventing damage to electronic components due to electrostatic discharge   AH54.00-P-0001-01A
  1. Route instrument cluster electric line (11) along vehicle wiring harnesses from device installation frame of the instrument cluster to the device installation frame of the head unit.

    NOTES Ensure wiring harness is routed correctly and free of chafing points.

    Otherwise, the instrument cluster electric line (11) may be damaged.

    IMPORTANT The curry yellow connector socket (12) is connected at a later stage connected to the instrument cluster.

    G13774960Courtesy of MERCEDES-BENZ USA
  2. Remove secondary fuse (10.1) at beige connector socket (10).

    IMPORTANT The secondary fuse (10.1) will be reused.

  3. Install instrument cluster electric line (11) into clamp "2" of beige connector socket (10).
  4. Mount secondary fuse (10.1) onto beige connector socket (10).

    IMPORTANT The beige connector socket (10) is connected at a later stage to the head unit.

    G13774961Courtesy of MERCEDES-BENZ USA