Remove/Install Left Engine Coolant Circulation Pump For Low-Temperature Circuit - AR09.41-P-6930MSA

Engine 256.9 in model 213, 238, 257, 290 

Fig 1: Left Engine Coolant Circulation Pump Component Location (Low-Temperature Circuit) - Engine 256.9 In Model 257
G14548235Courtesy of MERCEDES-BENZ USA
WARNING Risk of injury  to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning  from swallowing coolant. Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.
AS20.00-Z-0001-01A
Topical note Information on preventing damage to electronic components due to electrostatic discharge   AH54.00-P-0001-01A
REMOVINGINSTALLING Remove/install     
1 Drain coolant from low-temperature circuit.   AR09.41-P-6834MSA 
2 Remove left front lamp unit. Engine 256.9 in model 213 AR82.10-P-4730LW
    Engine 256.9 in model 238 AR82.10-P-4733LWO
    Engine 256.9 in model 257, 290 AR82.10-P-4733FR
3 Remove coolant hose (3) from low-temperature circuit circulation pump 2 (M43/7)   AR09.41-P-1311-01AL 
4 Release electrical connector (1) and disconnect.    
5 Unclip electric line from the bracket (2).    
6 Remove screw (5). TORQUE SPECIFICATION Bolt, holder for circulation pump to cross member *BA20.10-P-1004-01MRT 
7 Remove coolant hose (4) from low-temperature circuit circulation pump 2 (M43/7)   AR09.41-P-1311-01AL 
8 Remove low-temperature circuit circulation pump 2 (M43/7) with the bracket (2).    
9 Remove low-temperature circuit circulation pump 2 (M43/7) from bracket (2). When replacing low-temperature circuit circulation pump 2 (M43/7).
TORQUE SPECIFICATION M6X1
*BA00.10-P-1002-04A 
10 Install in the reverse order.    
METRIC SCREWS/BOLTS AND NUTS AS PER MBN 10 105, 10 143

Number Designation 8.8 10.9
BA00.10-P-1002-04A M6X1 Nm 9 13
COOLANT THERMOSTAT, COOLANT PUMP

Number Designation Engine 256
BA20.10-P-1004-01MRT Bolt, holder for circulation pump to cross member Nm 12