Home >> Mercedes Benz >> 2021 >> CLA45 AMG >> Repair and Diagnosis >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> Sliding Roof, Soft Top, Top Attachments -- 118 Chassis >> Basic Knowledge >> Open/Close Roof Roller Sunblind, Basic Function - GF77.20-P-9902A

Open/Close Roof Roller Sunblind, Basic Function - GF77.20-P-9902A

Model All (CAR) 

with code 413 (Panoramic sliding sunroof/glass roof) 

Overview 

This document contains information on:

General 

With the roller sunblind, the panoramic sliding sunroof located above this can be covered. It serves for the privacy and sun protection of the vehicle occupants and is driven by an electric motor.

Function requirements 

IMPORTANT

Control unit power-down 

After circuit 15 R OFF, the roller sunblind can still be operated for 5 min via the roof system switch.

IMPORTANT

The roller sunblind must be normalized for all automatic functions. The normalization ensures that the roller sunblind position can be precisely determined.

The roller sunblind position can not be determined in the denormalized status. The function is then limited to a gradual manual opening and closing.

Function 

Open/close roller sun blind 

The roller sunblind can be continuously variably opened or closed manually and automatically via different control elements or functions.

Control element/function Action Additional information
Roof system switch (actuated up to actuation point and held) Actuation for the duration of operation (max. 20 s) -
Roof system switch (actuated beyond actuation point and released) Actuation until end or memory position is reached -
Web-based via browser (e.g. tablet/PC/smartphone)
(vehicles with Remote Online)
Actuation according to application The roller sunblind status can be called at any time.
    This telematics service is realized on-vehicle via a cellular connection to the Service Center.
Convenience feature Actuation together with the side windows -

IMPORTANT

If the roof system switch is actuated for more than 60 s, the actuation is aborted. In the case of a permanent request, this is evaluated as a defect in the roof system switch. A new actuation (triggered via the roof system switch) can only be performed again after detecting that the roof system switch is in the rest position.

All automatic functions can be canceled by a repeat or different request.

The normalized roller sunblind has an automatic reversing function. This function protects against injuries or damage due to pinching. Once pinching is detected, the roller sunblind is either just stopped (during opening) or stopped and then opened again (during closing).

In the denormalized status, solely the permanently stored blockage detection protects the component parts of the roller sunblind against overloading.

Memory function 

The roller sunblind position is saved by the system at the end of a manual adjustment. The last saved position is moved to in the case of the automatic opening of the roller sunblind. The saved position is overwritten by every manual adjustment.

  Additional basic functions     
  Normalize electrically driven component parts, basic function   GF82.00-P-1000A
  Blockage detection, basic function   GF82.00-P-1001A
  Automatic reversing, basic function   GF82.00-P-1002A
  Panoramic sliding sunroof control unit, basic function   GF77.21-P-9891A 
  Roof roller sunblind drive unit, basic function   GF77.20-P-2015A