Remove Contacts From Siemens ELO Coupling - AR00.19-P-0120-23A
Model All
Unfasten secondary release on version with secondary retainer
- Use a suitable tool to reach into the secondary lock (1) and slide in direction of arrow towards pre-locking position (1a).
Unfasten secondary release on version with securing clip
- Using a suitable tool, pry up the side tabs of the retaining clamp (1).
- Slide securing clip (1) upwards.
- Remove securing clip (1).
Unpin female contacts from coupling
- Attach blade holder with
clamping pliers and
MQS blade at side of spring shackle of female contact (2).