Remove/install seal at inner C-pillar upper section for Vario roof - AR77.50-P-6768RK
MODEL 231
| Remove | |||
| Risk of injury caused by body parts being trapped or crushed when working on a partially open Vario roof (in stop mode) or in its closing area as a result of the Vario roof suddenly collapsing | Secure Vario roof with a suitable special tool. | AS77.50-Z-0001-01A | |
| 1 | Move Vario roof into intermediate position with the vario roof switch (S84s1) | ||
| 2 | Secure Vario roof with support (4) | Figure | |
| Figure | |||
| 3 | Remove paneling (3) from C-pillar upper section (2) | AR77.50-P-6763W | |
| Figure | |||
| 4 | Unclip paneling (5, 6) and remove | ||
| 5 | Separate water drain hose from seal (1) at bottom rear (arrow) from water drain funnel (8) | ||
| 6 | Slide seal (1) up 10 mm at flange on rear window side and unhook from C-pillar top section (2) (arrow A) | ||
| 7 | Remove seal (1) from flange in rear window side from C-pillar top section (2) and pull water drain funnel (8) on seal (1) out of C-pillar top section (2) | ||
| 8 | Loosen seal (1) toward front at lower flange and remove from C-pillar top section (2) (arrow C) | ||
| Clean | |||
| 9 | Thoroughly clean sealing surfaces of C-pillar top section (2) | The sealing surfaces must be free of oil and grease. Otherwise leakage is possible. Cleaner |
*BR00.45-Z-1025-04A |
| Install | |||
| 10 | Position new seal (1) starting at C-pillar top section (2) at front bottom (arrow C), hook pin (9) into cutout (arrow H) and hole (10) in pin (arrow J) | ||
| 11 | Slide seal (1) on C-pillar top section (2) along assembly rail (arrows D) in direction of water drain funnel (8) | ||
| 12 | Press water drain funnel (8) on seal (1) into hole (11) | ||
| 13 | Hook seal (1) into pins (arrow G) | ||
| 14 | Slide seal (1) on side of rear window flange on C-pillar top section (2) upward (arrow C) | ||
| 15 | Clip in (7) on seal (1) into retaining rail on upper flange of C-pillar top section (2) by hand and hook sealing lip (12) into upper area (arrow A) | ||
| 16 | Install paneling (3) on C-pillar top section (2) | AR77.50-P-6763W | |
| Figure | |||
| 17 | Install water drain hose at bottom rear (arrow B) on water drain funnel (8) | ||
| 18 | Remove support (4) | ||
| 19 | Completely close Vario roof with Vario roof control switch (S84s1) | ||
| 20 | Visually check seal seating (1), parallel course and lip contact (wave formation) | ||
| 21 | Perform rain test |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1025-04A | Cleaner | A 005 989 19 71 |