Remove/install circulation pump for low-temperature water circuit - AR09.41-P-6925MUB
MODEL 217 with ENGINE 279
MODEL 222 with ENGINE 277, 279
| Remove/install | |||
| 1 | Drain coolant from low-temperature circuit | AR09.41-P-6834MUB | |
| 2 | Disconnect electrical connection (4) from circulation pump (5) | ||
| 3 | Detach coolant hoses (1) at circulation pump (5) | ||
| 4 | Remove screw/bolt (2) | ||
| 5 | Remove bracket (3) | ||
| 6 | Remove circulation pump (5) downwards | ||
| 7 | Install in the reverse order | ||
| Check | |||
| 8 | Check low-temperature circuit for leaktightness | AR09.41-P-1010MUB | |
| Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | AS00.00-Z-0005-01A | |
| 9 | Perform an engine test run and check low-temperature circuit cooling system for proper function |