LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2020 >> GLS580 >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Electrical System, Equipment & Instruments - 167 Chassis (2 Of 4) >> Testing & Repair >> Remove/Install Contact Socket For Plug Of Electropneumatic Controller Unit - AR54.18-P-0017-01ME

Remove/Install Contact Socket For Plug Of Electropneumatic Controller Unit - AR54.18-P-0017-01ME

Model 167 With Code 489 (AIRMATIC Dual Control/semi-active air suspension) except code 490 (Electrohydraulic suspension) 

Model 167 With Code 489 (AIRMATIC Dual Control/semi-active air suspension) With Code 490 (Electrohydraulic suspension) 

Model 206 With Code 480 (Self-levelling suspension) 

Model 223, 296, 297 

Model 254 With Code 480 (Self-levelling suspension) 

Model 254 With Code 489 (AIRMATIC Dual Control/semi-active air suspension) 

Notice  Information on preventing damage to electronic components due to electrostatic discharge   AH54.00-P-0001-01A
  Notes on safety-relevant components   AH00.00-Z-0019-01A
Fig 1: Identifying MCP 2.8_/Fl. Blade 2.8_/JPT/SPT (000 589 13 99 30)
G12923831Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying MCP 1.2_Blade (220 589 04 99 30)
G14791191Courtesy of MERCEDES-BENZ USA

NOTES Transfer the contact sockets individually one after the other.

Otherwise, it may lead to confusion.

G14791192Courtesy of MERCEDES-BENZ USA
G14791193Courtesy of MERCEDES-BENZ USA

IMPORTANT The contact socket assignment can vary depending on the equipment variant.

Remove 

  1. Release contact lock of old housing (1) (arrow a).
  2. Release contact socket (5) with SPECIAL TOOL MCP 1.2 blade (3) and pull out of contact cavity (4).

    If a contact socket (5) is removed in area (A).

    NOTESSPECIAL TOOL Insert MCP 1.2 blade (3) vertically into contact cavity (4) and do not apply any leverage.

    Otherwise damage may occur.

  3. Release contact socket (5) with SPECIAL TOOL MCP 2.8_/Fl. 2.8_/JPT/SPT blade (2) and pull out of contact cavity (4).

    If a contact socket (5) is removed in areas (B, C).

    NOTESSPECIAL TOOL Insert MCP 2.8_/Fl. 2.8_/JPT/SPT blade (2) vertically into contact cavity (4).

    Otherwise damage may occur.

    Install 

  4. Push contact socket (5) all the way into contact cavity (4) of new housing (1).

    NOTES The contact socket (5) in area (A) must not be removed afterwards.

    Otherwise, the mat seal will be damaged and the housing (1) will have to be replaced.

    IMPORTANT Ensure that the contact socket (5) is seated and positioned correctly in the contact cavity (4).

    IMPORTANT When the contact socket (5) engages correctly, a "click" should be heard.

  5. Check contact socket (5) is correctly seated by carefully pulling.

    NOTES Pull carefully and in a controlled manner.

    Otherwise, the contact socket (5) or the contact cavity (4) could be damaged.

  6. Lock contact lock of housing (1) (arrow b).