Remove/Install Battery Sensor - AR54.10-P-0002ME
Model 167
MODIFICATION NOTES
| 13.07.2021 | New operation step inserted. | Step 6 |
| Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | AS00.00-Z-0035-01A | |
| Risk of fire /risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notice | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | AH00.00-Z-0300-01A | |
| Notice | Notes on battery | AH54.10-P-0001-01A | |
| Notice | Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | |
| Notes on safety-relevant components | AH00.00-Z-0019-01A | ||
| Remove/install | |||
| 1 | Disconnect ground line (1) from on-board electrical system battery (G1). | AR54.10-P-0003ME | |
| 2 | Release and disconnect electrical connector (2) from battery sensor (B95). | ||
| 3 | Remove nut (3) from battery ground point (W10). | ||
| *BA00.19-P-1050-01M | |||
| Fig 2 | |||
| 4 | Route out ground line (1) with battery sensor (B95) and remove. | ||
| 5 | Install in the reverse order. | ||
| 6 | Commission battery sensor (B95). | When replacing battery sensor (B95). | |
| AD00.00-P-2000-06ME |
GROUND POINTS
| Number | Designation | Model 167 | ||
|---|---|---|---|---|
| BA00.19-P-1050-01M | Battery ground point | W10 | Nm | 16 |