Home >> Mercedes Benz >> 2020 >> GLE350 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 239 (Brakes - Hydraulic & Mechanical System - 172 Chassis - 1 Of 2) >> Testing & Repair >> Detach/Mount Connector - AR42.45-P-0820-02CW

Detach/Mount Connector - AR42.45-P-0820-02CW

WARNING: This page is about a different car, the 2020 Mercedes-Benz SLC43 AMG, 2019 Mercedes-Benz SLC43 AMG, 2018 Mercedes-Benz SLC43 AMG, and 2017 Mercedes-Benz SLC43 AMG. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 204, 172 

G13845925Courtesy of MERCEDES-BENZ USA

Shown on Model 204 

Disconnect electrical connector 

NOTES If the bracket (1), connector (2) or connector locking mechanism is damaged, it is essential to replace the damaged parts. The connector (2) can otherwise become detached from the Electronic Stability Program control unit (N30/4).

  1. Remove cap of connector.
  2. Open the connector locking mechanism; to do this, press both release buttons (1e) carefully from the bottom upwards.

    IMPORTANT Do not use tools. Do not open the snap-in bracket (1n).

  3. Swivel bracket (1) upwards approx. 90°.

    IMPORTANT The connector (2) is pushed slightly out of the jack (3) on the Electronic Stability Program control unit (N30/4).

  4. Pull connector (2) out of jack (3).

    NOTES When doing so, do not grip the connector (2) by the bracket (1). The bracket (1) and connector locking mechanism can otherwise be damaged.

  5. Swivel bracket (1) downwards until the connector locking mechanism latches.

    Connect electrical connector 

  6. Open the connector locking mechanism; to do this, press both release buttons (1e) carefully from the bottom upwards.

    IMPORTANT Do not use tools. Do not open the snap-in bracket (1n).

  7. Swivel bracket (1) upwards approx. 90°.
  8. Insert connector (2) into jack (3) on Electronic Stability Program control unit (N30/4) until connector makes contact evenly along its entire length with base of jack (3).

    NOTES When doing so, do not grip the connector (2) by the bracket (1). The bracket (1) and connector locking mechanism can otherwise be damaged.

  9. Swivel bracket (1) downwards until the connector locking mechanism latches.

    IMPORTANT The connector (2) is drawn into its end position and locked.

  10. Attach cap of connector.