Apply Thermal Compound To DC/DC Converter For 48 V On-Board Electrical System - AR54.10-P-1351-01LWO
Model 205, 213, 238, 253
with code B01 (48V technology)
| Notes on safety-relevant components | AH00.00-Z-0019-01A |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1002-14A | Thermal compound | A 222 989 00 00 |
Before beginning the following work instruction, the DC/DC converter control unit must be completely freed of old thermal compound and cleaned.
- Mark fill level of thermal compound on double cartridge (1).
- Break off latch (2).
Note maximum of 1 h processing time.
- Screw mixing spout (3) onto double cartridge (1).
- Insert double cartridge (1) into a commercially available 50 ml double-cartridge gun and completely fill mixing spout (3) with thermal compound.
- Apply half of cartridge content, approx. 6.2 ml, onto DC/DC converter control unit (N83/1) in area (B).
- Apply 60 % of remaining cartridge content, approx. 4.1 ml, onto DC/DC converter control unit (N83/1) in area (A).
- Apply remaining cartridge content, approx. 2.6 ml, onto DC/DC converter control unit (N83/1) in area (C).
Approx. 2.1 ml of thermal compound is left in the mixing spout.