Remove/Install Fluid Reservoir - AR83.30-P-6520LWB
Model 213 with code 1U6 (R744 refrigerant)
| Risk of injury when working on air conditioning systems due to R744 refrigerant escaping under pressure. Risk of suffocation from inhaling R744 refrigerant in high concentrations. Health hazard caused by inhalation of R744 refrigerant | Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | AS83.00-Z-0008-01A | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | AH83.30-N-0005-01A | ||
| Notes on avoiding damage through contamination and foreign objects | AH00.00-P-5000-01A | ||
| Notes on handling refrigerant R744 | AH83.30-P-0003-03A | ||
| Remove/install | |||
| 1 | Drain air conditioning system | AR83.30-P-1760LW | |
| 2 | Unscrew the screws (2, 3) of the refrigerant line (10, 11) | ||
| *BA83.30-P-1015-01R | |||
| 3 | Remove the refrigerant line (10, 11) from the fluid tank (1) | ||
| 4 | Seal openings with suitable stop plugs | Fig 2 | |
| 5 | Remove the screw (7) from the bracket (12) | *BA83.30-P-1017-01R | |
| 6 | Unscrew nuts (15) | *BA83.30-P-1016-01R | |
| 7 | Unclip the electrical lines at the bracket (12) | ||
| 8 | Remove the bracket (12) including fluid tank (1) from the studs on the wheel arch | ||
| 9 | Remove the bracket (12) and fluid tank (1) unit towards the top | ||
| 10 | Install in the reverse order |
AIR CONDITIONING
| Number | Designation | Model 213 with code 1U6 (R744 refrigerant) | |
|---|---|---|---|
| BA83.30-P-1015-01R | Refrigerant line (CO2) to refrigerant reservoir | Nm | 12 |
AIR CONDITIONING
| Number | Designation | Model 213 with code 1U6 (R744 refrigerant) | |
|---|---|---|---|
| BA83.30-P-1016-01R | Nut, bracket for refrigerant reservoir CO2 to body | Nm | 4 |
AIR CONDITIONING
| Number | Designation | Model 213 with code 1U6 (R744 refrigerant) | |
|---|---|---|---|
| BA83.30-P-1017-01R | Bolt, bracket to refrigerant line CO2/refrigerant reservoir CO2 | Nm | 8 |