Retrofit Electrical Wiring Harness Of Illuminated Door Sill Molding With Mercedes-Benz Lettering - AZ82.20-P-0005-01FR
Model 257.3
| Topical note | Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | |
| Topical note | Notes on the use of paint scraping nuts on ground connections | AH00.19-P-1000-20A |
| Number | Designation | Model 257 | ||
|---|---|---|---|---|
| BA00.19-P-1013-02D | Right front footwell ground point | W15/7 | Nm | 10 |
Connection scheme
Routing diagram
- Cut off both blue 2-pin plugs (2.3) and insulate lines.
Both blue 2-pin plugs (2.3) are not required.
- Open front right cable duct.
- Place wiring harness for illuminated door sill molding (2) into front passenger footwell.
- Route brown line (BN) to right front footwell ground point (W15/7) and fix in place with cable ties.
- Connect brown line (BN) at right front footwell ground point (W15/7)
.
A maximum of 5 connectors may be connected to a ground point. If too many have been used, select another ground point.
- Route right illuminated door sill molding branch-off line (2.2) along existing lines through cable duct and fix in place with cable ties.
Route the right illuminated door sill molding branch-off line (2.2) in such a way that the black 2-pin plug (2.8) can be clipped into the provided cutout later.
- Route illuminated door sill molding wiring harness (2) into driver footwell.
Use a pull-through device.
- Route black 18-pin connector socket (2.4) to illuminated door sill molding control unit, and fix in place.
- Attach black 18-pin connector socket (2.4) to illuminated door sill molding control unit (1).
- Open front left cable duct.
- Route illuminated door sill molding wiring harness (2) to left A-pillar, and fix in place with cable ties.
- Route left illuminated door sill molding branch-off line (2.1) along existing lines through the cable duct and fix in place with cable ties.
Route left illuminated door sill molding branch-off line (2.1) in such a way that the black 2-pin plug can be clipped into the provided cutout later.
- Route twisted brown line (BN) and brown/red line (BN/RD) to the potential distributor interior CAN (CAN B) (X30/32) and fix in place with cable tie.
- Attach black 2-pin connector socket of twisted brown line (BN) and brown/red line (BN/RD) to any free slot of left interior CAN (CAN B) potential distributor (X30/32).
If no slots are free.
↓
Remove any black 2-pin connector from left interior CAN (CAN B) potential distributor (X30/32), and connect potential distributor extension (3) using adapter P82.20-4760-12 line (4). Connect detached black 2-pin connector socket and black 2-pin connector socket of twisted brown line (BN) and brown/red line (BN/RD) to potential distributor extension (3).
Potential distributor extension (3) and adapter line (4) are included in installation kit.
- Route red line (RD) to driver side fuse and relay module (K40/6), and fix in place with cable ties.
- Check whether contact for fuse holder is assigned in driver side fuse and relay module (K40/6).
If contact is not used.
↓
Remove lock (20) on driver side fuse and relay module (K40/6), install electrical jumper (21) in slot "S7" and chamber "9" of driver side fuse and relay module (K40/6), and install lock (20).
Slot "S7" and chamber "9" of driver side fuse and relay module (K40/6) are labeled.
- Attach red fuse holder (2.6) at slot "S7" of driver side fuse and relay module (K40/6).
Slot "S7" of driver side fuse and relay module (K40/6) is labeled.
- Insert fuse with fuse rating of 5 A into red fuse holder (2.6).