Home >> Mercedes Benz >> 2019 >> Sprinter 3500XD 2D Cab Chassis >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System, Equipment & Instructions - Description & Operation, Location, Gen Info & Basic Knowledge >> Basic Knowledge >> Functional Scope Of Logic Functions (Plc), PSM, Function - GF54.21-D-3008TSA

Functional Scope Of Logic Functions (Plc), PSM, Function - GF54.21-D-3008TSA

Model 907 

with code ED5 (Parameterisable special module) 

Function overview 

The parameterizable special module (PSM) provides functions of the programmable logic control (PLC). Using these software functions, the customer can realize simple logical operations between signals in the parameterizable special module's signal pool.

The PLC functions can be coded; this means that the input signals of the PLC can be freely selected by the customer from the signal pool.

With some blocks, it is also possible to set parameters such as thresholds and times.

All logic function blocks with the following functions with quantity: 

Logic function blocks 

The logic function blocks are subdivided into 12 identically structured groups.

Processing takes place sequentially in groups by ascending group number.

After a group has been processed, the results of the processing are available in the signal pool and can be used further by one of the subsequent groups.

Cycle times of the configuration blocks 

Using the PLC configuration tool 1, a corresponding coding string can be generated for the data entry of the configuration blocks.

Description of logic configuration block 

Every logic configuration block consists of 4 identically constructed groups with various function blocks.

Description of group 

Every group can be activated individually.

One group comprises the following function blocks:

The assignment of the input signals and the configuration of the function blocks take place by diagnosis.

The functions of the individual function blocks are described in the following documents:

Filter function 

The filter functions for various inputs of the function blocks are constructed identically, but can be coded individually.

A filter block is always active. If one or more filter parameter bits are set (where state does not equal "0"), the corresponding filter signal is also evaluated as an input signal (logical "AND").

Filter signals 1 to 3 have a special position, as they represent the non-inverted outputs of logic blocks and are therefore variable in their configuration.

If filter bit 8 is set, the logically inverted input signal is used.

FILTER FOR INTERNAL INPUT

No. Filter Description of output
1 Group 12 logic block 1 Takes into consideration the state of
  output A output A (non-inverted output) of group 12 logic block 1.
2 Group 12 logic block 2 output A Takes into consideration the state of output A (non-inverted output) of group 12 logic block 2.
3 Group 12 logic block 3 output A Takes into consideration the state of output A (non-inverted output) of group 12 logic block 3.
4 CiA447 active Bit is set if CiA447 CAN is active.
5 Terminal change from terminal 15R to terminal 15 Bit is set with a change of terminal from terminal 15R to terminal 15; the reset reverts automatically after 3 PLC polling cycles.
6 No overtemperature The bit is set provided no overtemperature is detected in the PSM.
7 Terminal 58 The bit is set provided the terminal 58 signal is not equal to "0".
8 Invert input signal The evaluation of the input signal is inverted.
9 CAN fault The bit is set as long as the control unit is operating in limp-home mode.
10 No undervoltage There is no undervoltage.
11 Terminal 61 Function for "Engine running".
12 terminal 15 Function as from "Ignition ON".
13 Terminal15R Function as from "Ignition key at radio position".
14 Terminal15C Function as from "Key in ignition".
15 Central locking (CL) open The CL status does not equal "Externally locked".
16 Run-on time active Function as long as at least one reason for the ECU remaining active (incl. run-on time) is active.

Logic configuration area 

The properties of the function blocks are compiled and configured in their own area within the logic configuration block.

Overview of system components for parameterizable special module (PSM) GF54.21-D-9998TSA